T E I D E
HP internal parameter
This is a manufacturing internal parameter. Under no circumstances may it be modified by the
user.
Touching the OK key in this last parameter will exit the Internal Parameters Configuration into the
selected Mode (1P or 2P).
During the configuration of the internal parameters, if no key is touched for 30 seconds, the emitter
will return to the previous mode of operation.
5.10 EASY MODE
Once the emitter is set into the Easy Mode, it will only allow the user to increase and decrease the
temperature setting, and set the emitter Operational or on Standby.
There is no access to the clock, mode or configuration changes and no keyboard lock, just the
heating icon showing if the emitter is currently heating and the current room temperature.
Only the Standby, p and q keys are operational.
The configuration values are set as shown below and cannot be modified in Easy Mode:
1 - Brightness level at rest: Level set in 1P (Normal Mode)
2 - Maximum brightness Time: Time set in 1P (Normal Mode)
3 - Open Windows: OFF
To modify the brightness values used by the emitter in Easy Mode (2P), they must be previously
set in Normal Mode (1P). The Open Windows function will always be disabled in Easy Mode, re-
gardless of its setting in Normal Mode.
The emitter temperature set point is adjustable with the
p and q keys between 12 °C and 30 °C, in steps of
0.5 °C.
6. ERRORS TABLE
There are 2 possible errors that the electronics can detect; if an error is detected one of the follow-
ing codes will be displayed on the screen until it is resolved:
ERROR
DESCRIPTION
CODE
Failure in microcontroller, EPROM or other PCB compo-
ERROR1
nent
Failure of the NTC probe (e.g. disconnected, short-cir-
ERROR2
cuited, etc.)
When recovering from an error, the emitter will always go to Standby, without retaining any previ-
ous mode or state. If the emitter goes to Standby without any specific reason, it may have recov-
ered from an error.