Dräger X-plore ADF 5-13 Instrucciones De Uso página 17

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 27
9
Disposal
This product must not be disposed of as household waste. This is indi-
cated by the adjacent symbol.
You can return this product to Dräger free of charge. For information
please contact the national marketing organizations or Dräger.
Batteries must not be disposed of as household waste. This is why the
ADF is marked with the symbol shown on the left. Dispose of batteries
at battery collection centers as specified by the applicable regulations.
10
Technical data
Operating/storage temperature:
Operating/storage area humidity:
Darkening stages
Setting range for delay time (dark
to light) of the ADF
Darkening time of the ADF
Dimensions
ADF
Visual range
Head circumference of the
support ring
Weight
Material
Head cover with face cuff
Sweatband
Visor
Instructions for use
|
Dräger X-plore
-10 °C to +55 °C (14 °F - 131 °F)
≤ 90 % relative humidity
4 (grind mode), 5 to 13 (weld mode) in
accordance with EN 379
0.1 s to 0.9 s
0.08 ms
90 mm x 110 x 8.5 mm
97 mm x 47 mm
50 cm to 62 cm
780 g
®1)
Proban
PU/cotton
PA
®
Welding Visor with ADF 5-13
External and internal protec-
tive screens
Battery
®
1)
Proban
is a registered trademark of Rhodia S.A.
Disposal
PC
Button cell type CR2450
|
en
17