Maintenance And Repairs - SATA SATAjet 3000 K spray mix Instrucciones De Servicio

Ocultar thumbs Ver también para SATAjet 3000 K spray mix:
Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 73
Operating instructions SATAjet 3000 K spray mix
EN

10. Maintenance and repairs

Risk of injuries from components coming loose or leaking
material.
If maintenance work is performed while the gun is still connected to the
compressed air circuit and material supply, components can unexpect-
edly work loose and material can leak.
→ Disconnect the spray gun from the compressed air circuit and the
material supply before any maintenance work.
→ Depressurise the system.
All parts of the spray gun that convey material, the material supply and
lines are under high pressure (up to 250 bar).
→ Hoses and connection systems must be rated accordingly.
Risk of injury from sharp edges
There is a risk of injury from sharp edges when fitting the nozzle set.
→ Wear protective gloves.
→ Always use the SATA extraction tool pointing away from your body.
The following chapter describes the procedures for maintaining and ser-
vicing the spray gun. Maintenance and service work may only be carried
out by specialist personnel.
■ Always interrupt the compressed air supply and the material supply
before performing any maintenance and repair work.
Spare parts are available for maintenance (see chapter 17).
10.1. Replace nozzle parts
Dismantle material nozzle
■ Unscrew air cap ring and contact protection [3-1] by hand.
■ Remove air cap [3-2] together with material nozzle [3-3].
38
Warning!
Warning!
Tabla de contenido
loading

Tabla de contenido