Assemble the struts (1) to the platform attachment points (2) with the clevises and fasteners
provided,
-
Place the clevises (3) on the transom and mark the position of the holes,
-
Remove the clevises and drill the four holes with a Ø4.5mm drill bit,
-
Clean the surfaces around the holes and apply SIKAFLEX,
-
Tighten the two clevises with the Ø4.8 screws supplied.
-
-
Clean the upper surfaces of the platforms,
-
Glue on the EVA pads supplied.
INSTALLATION
Page 58 / 63