SYSTEM INSTALLATION
This chapter describes the system equipment installation, cable connections, and relevant precautions:
- Installing the ZS-200M on a Fixed Surface (Optional)
- Connecting the Protective Grounding Cabinet Wires
- Installing the ZS-2000M and ZS-1500/ ZS-2250/ ZS-4125 in the Appliance Cabinet
- Connecting the Protective Grounding
- Connecting the System Components
- Connecting the Power Supply
Note:
- The electricity and power sources must be turned off when performing the following tasks to avoid
electric shocks and damage to the equipment.
- Turn off all equipment power supply switches prior to wiring.
- Correctly connect the wiring terminals and tighten the screws.
- The power supply cables and signal data lines must be separated, and cannot be laid in the same
slot or piping.
- Control signal cables must be positioned away from 100V audio or power supply cables to avoid
signal interference.
- Appropriate materials, such as plastic ties, must be used for all connection cables for reinforcement
to avoid looseness. When moving the cables, prevent the power supply cables from coming in
contact with the signal data cables.
- Install appropriate electrical cables bushings at the cabinet opening before installing the cables in
the appliance cabinets.
- Appropriate materials must be used to block the spaces reserved for the cables at the cabinet
opening if these spaces are not used.
INSTALLING THE ZS-200M ON A FIXED SURFACE (OPTIONAL)
If it is unnecessary to move the ZS-200M often, mount the ZS-200M in a fixed surface, such as a desk. The
installation steps are as follows:
1. Cut a slot for the ZS-200M to fit in on the desk surface. The slot is required to be 198mm long and 100mm
wide, as shown in Figure 4.
Figure 4 Schematic Diagram of Creating a Slot for Seating the ZS-200M (Level Surface)
Figure 5 Schematic Diagram of Creating a Slot for Seating the ZS-200M (Slanted Surface)
2. Adequate space for wires connecting to the ZS-200M must be reserved on the rear side of the unit. If the
surface thickness is greater than 10mm, the space reserved for the wires must be about 80mm long and
10mm wide, as shown in Figure 6.
Figure 6 Schematic Diagram of the Reserved Space for the Rear Panel Wire Connections
- 7 -