FONESTAR ZS-2000M Manual De Instrucciones página 15

Central megafonía y alarma por voz en 54
Ocultar thumbs Ver también para ZS-2000M:
Tabla de contenido
Idiomas disponibles

Idiomas disponibles

Figure 22 Schematic Diagram of the ZS-2000M and Three-Line Volume controller Connection
Figure 23 Schematic Diagram of the ZS-2000M and Four-Line Volume controller Connection
ZS-4328IO Dry Contact Output Preparation
The dry contact output of ZS-4328IO can be configured as fault signal output which will be connected with
fire alarm system, and delivery the system fault status. The NO and COM of a dry contact output will be
used.
1. Strip off the wire jacket of one end of prepared dry contact output cable by about 10mm, insert dry
contact wiring terminal (6P green euroblock connector of 3.5mm), and tighten the screws.
2. Insert the dry contact output wiring terminal of the installed output cable into the ZS-4328IO dry contact
port.
3. Connect the fire alarm system. Figure 24 is schematic diagram of the ZS-4328IO and fire alarm system
connection.
Figure 24 Schematic Diagram of the ZS-4328IO and fire alarm system Connection
- 15 -
EN
Tabla de contenido
loading

Tabla de contenido