WATER CONNECTION

3/4"
3/4"
A
B
C
D
Fig. 9
The water used should have the following properties:
PH 6.5÷7.5
Chlorides < 150mg/litre
Chlorine concentration 0.2÷0.5 mg/litre
Conductivity 200÷2000 µS
Water impurities Ø < 0.08 mm
Water hardness 5- 10ºF
Recommended filters:
A) Fine filter.
If the water contains impurities such as sand, iron particles or floating
substances, we recommend the use of a fine filter at the water input.
B) Activated carbon filter.
If the water has a high chlorine content over 0.2 mg/l (ppm) (this information can
be obtained from the relevant water board), an activated carbon filter should be
installed.
C) Installation of osmosis recirculation.
When the chloride concentration is above 150 mg/l (ppm) (this information can be
obtained from the relevant water board), an osmosis recirculation installation
should be mounted. In this case, please remember that the minimum conductivity
value is 200 µS/cm.
VISUAL PLUS INSTRUCTIONS MANUAL
1
300kPa
R3/4"
Manguera entrada agua
Water inlet hose
Only connect drinking water to the
appliance.
Connect the appliance to the mains
water supply at point 1 (Fig. using the
hose supplied.
The pressure of the incoming water
should be between 200 and 400 kPa
2
(2-4 kg/mm
). We recommend 200 kPa.