Fagor VISUAL PLUS VPE-061 Manual De Instrucciones página 69

Ocultar thumbs Ver también para VISUAL PLUS VPE-061:
Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

ENGLISH
E5: WATER LEVEL
DESCRIPTION
Water is detected at the maximum level but not at the minimum level.
CONSEQUENCE
It is only possible to operate in Convection mode
E6: CALIBRATION
DESCRIPTION
It was not possible to calibrate in 15 minutes.
CONSEQUENCE
The oven continues to function normally
E7: ERROR A.E.
DESCRIPTION
The variator frequency input (A.E.) has been observed not to function.
The connection has been cut off
If the motor does not start within 10 seconds of a start request.
If a speed of 500 rpm is not exceeded within 20 seconds of a start request.
CONSEQUENCE
The oven is completely disabled
E8: WATER REQUIRED
DESCRIPTION
The VDV is observed to have been running for 7 or more minutes and the maximum
level has not been reached.
CONSEQUENCE
It is only possible to operate in Convection mode
E9: DRAINAGE ERROR
DESCRIPTION
The VAC is observed to have been running for 1 or more minutes and the minimum
level has not been reached.
CONSEQUENCE
It is only possible to operate in Convection mode
E10: ERROR CV
DESCRIPTION
If TG<93ºC, when CV is active, in 3 minutes, TG does not rise 3 or more degrees.
CONSEQUENCE
It is only possible to operate in Convection mode
VISUAL PLUS INSTRUCTION MANUAL
.
69
Tabla de contenido
loading

Tabla de contenido