Sufficient water level has not been reached within 10 minutes after the device has been turned
E14
on. Clean the measurement cup and check the wiring.
Sufficient water level won't be reached when vaporising. Check the water inlet* and discharge valve.
E15
WiFi indicator light is off: WiFi connection is off in the S-CO setup menu.
WiFi indicator light is on: WiFi connection is on. Connections to the router and MyHarvia cloud are
working.
WiFi indicator light flashes 3 times in a row: WiFi connection is on, but connection to MyHarvia cloud
fails. Check your internet connection*. Try restarting your router*.
WiFi indicator light flashes every 5 seconds: The Wi-Fi connection is on, but the wifi connection
between the control panel and the router fails. Try fixing the connection by turning off and on the WiFi
connection in the control panel S-CO setup menu*.
Maintenance indicator light starts blinking when 200 hours has passed from the previous service. Perform
service. Reset counter after service.
Several errors: Error messages run in the display.
Water reservoir smells like the fragrance: Check that fragrance doesn't flow to the water reservoir from the
EN
steam pipe.
Control panel disfunction: » Factory Reset
Resetting the overheat protector
The reason for the going off must be determined before the button is pressed. The overheat
protector may be reset only by a professional maintenance person.
1 .
56
2 .