3 . INSTALLATION (2)
ENG
The pump can rest on the flat bottom surface of a tank.
When sand or silt deposits are expected to form, mount the pump on a true lower level surface so that
abrasive material is not lifted.
The pump can be kept in a suspended position by the metal supply pipe. Tighten the threaded joints of
the pipes securely to prevent loosening during operation.
Place the pump at least 0.5 m from the bottom of a well to prevent sand from rising.
A safety rope or chain of non-perishable material should always be used to secure a suspended pump.
When using a plastic or flexible delivery pipe, the safety rope or chain should be used to lower, secure
and lift the pump.
WARNING:
Never use the power cord to suspend the pump.
Connect the power cable to the supply pipe and to the safety rope with cable clamps at intervals of
approximately 3 m. The power cable must not be taut: allow a certain degree of slack between the
clamps to avoid the risk of deformation caused by expansion of the tube during operation.
1. Electrical cable
2. Supply tube
3. Safety rope
4. Pressure gauge
5. Air vent valve
7. Gate valve