Release the clamping lever and then switch the machine to counter-clockwise
rotation (press the counter-clockwise rotation button) if the tool gets stuck in the
blockage!
Loosen the tool stuck in the blockage by moving the spiral back and forth and rotating it right
/ left with the clamping lever pressed.
The LEDs in the frame will start to flash if the battery charge level is too low (see Trou-
bleshooting).
5.11
Shut-down
Keep the button pressed down for 2 seconds to deactivate the controller and then remove
the battery.
Remove the guide tube from the device.
5.12
Charger and battery
Overview:
1
Battery pack
2
Sliding seat
3
Operation display
Start of operation
Before plugging in, check to see that the rated mains voltage and mains fre-
quency, as specified on the rating label, match your power supply.
Devices such as this one, which generate direct current, may have an effect on basic residual-
current circuit breakers. Use type F or better, with a release current of max. 30 mA.
Before commissioning the charger, ensure that the air slots are free. Minimum
distance to other objects is 5 cm/ 2".
Self-test:
Insert mains supply plug.
The warning display (4) and the operating indicator (3) light up one after the other for approx. 1
second and the installed fan runs for approx. 5 seconds.
Battery pack:
Charge the battery pack before use (1).
If performance diminishes, recharge the battery pack.
The ideal storage temperature is between 10°C / 50° F and 30°C / 86° F. The permissible stor-
age temperature is between 0°C and 50°C / 32° - 122° F.
Li-ion battery packs have a capacity and signal indicator: (6)
Press the button (5), the LEDs indicate the charge level.
If one LED is flashing, the battery pack is almost flat and must be recharged.
Handling
Charging battery pack:
Push the battery pack completely to the stop on the sliding seat (2).
The operating indicator (3) flashes.
Conservation charge:
Once the charging process has finished, the battery charger automatically switches to conserva-
tion mode.
The battery pack can remain in the battery charger and is therefore always ready for use.
The operating display (3) lights up continuously.
4
Warning display
5
Capacity indicator button
6
Capacity and signal indicator
ENGLISH
(H)
25