Kohler K-10949 Guia Del Usuario página 21

Válvula electrónica
Ocultar thumbs Ver también para K-10949:
Tabla de contenido
Idiomas disponibles

Idiomas disponibles

Troubleshooting (cont.)
Symptom
Probable
Cause
6.
Water
A. Arm to
leaking
control
from valve
stop seal is
inlet.
worn or
damaged.
7.
LED signal
A. Repeats
from
once per
sensor.
second
when in
range of
sensor and
valve
activates.
B. Repeats
once per
second
when in
range of
sensor and
valve does
not
activate.
Kohler Co.
Recommended Action
• Turn off the water supply.
• Purge the valve.
• Disconnect the valve from the
control stop.
• Inspect the O-ring seal for the
control stop to inlet connection.
• Clean any debris from area.
• If the O-ring is cut or torn,
order a replacement.
• Reassemble the unit, taking
care to tighten the nut onto the
control stop.
• Batteries are low.
• Follow the directions of
"Replace the Batteries" section
in this guide.
• Batteries life expired.
• Follow the directions of
"Replace the Batteries" section
in this guide.
21
1104277-5-B
Tabla de contenido
loading