Kohler K-10949 Guia Del Usuario página 20

Válvula electrónica
Ocultar thumbs Ver también para K-10949:
Tabla de contenido
Idiomas disponibles

Idiomas disponibles

Troubleshooting (cont.)
Symptom
Probable
Cause
3.
Constant
A. Filter is
flow.
plugged.
B. Diaphragm
seal is
dirty or
damaged.
C. Solenoid
not
working.
Sporadic
A. Wires are
4.
flow.
pinched or
damaged.
B. Low
battery.
5.
Water
A. Vacuum
leaking
breaker is
from the
defective,
vacuum
worn, or
breaker
damaged.
connection
with valve.
1104277-5-B
Recommended Action
• Follow the directions of "Clean
the Screen/Replace the Piston"
section in this guide.
• Follow the directions of
"Clean/Replace the
Diaphragm" section in this
guide.
• NOTE: Take care to replace the
diaphragm in its seat before
installing it into the valve body.
• If the diaphragm is cut or torn,
order a new diaphragm
assembly.
• Order and install a new
solenoid assembly.
• Follow the directions of
"Remove the Solenoid" and
"Install the Solenoid" sections
in this guide.
• Remove the valve cover.
• If wires are cut or damaged,
order new solenoid or sensor
assembly.
• Verify that both wires are
tucked inside the cover before
reassembling.
• Follow the directions of
"Replace the Batteries" section
in this guide.
• Turn off the water supply.
• Purge the valve.
• Disconnect the valve from the
vacuum breaker assembly.
• Replace rubber vacuum
breaker.
• Reassemble the valve to the
vacuum breaker assembly.
20
Kohler Co.
Tabla de contenido
loading

Tabla de contenido