Kohler K-10949 Guia Del Usuario página 11

Válvula electrónica
Ocultar thumbs Ver también para K-10949:
Tabla de contenido
Idiomas disponibles

Idiomas disponibles

Cap
DC Sensor
Connector
Retaining Nut
Solenoid
Connector
Pin
Diaphragm
Install The Solenoid
NOTICE: Do not overtighten the solenoid, as damage to the
solenoid can occur.
NOTICE: Do not pinch or kink the wires between the cap and the
valve body. If the wires are damaged, the unit may not operate.
Align the solenoid to the hole in the piston cover.
Install the solenoid and tighten with an adjustable wrench by
turning clockwise.
Connect the DC sensor connector to the solenoid connector and
locate the connector assembly next to the sensor body to avoid
pinching.
Place the cap on the valve body and secure with the setscrew.
Open the control stop valve (refer to the "Control Stop Valve
Operation" section).
Verify that the valve functions.
Kohler Co.
Setscrew
Solenoid
Assembly
Spring
Valve Body
11
O-Ring
Piston
Cover
Piston
1104277-5-B