Safety input and command status (TEST mode)

DISPLAY
POSSIBLE CAUSE
The safety STOP contact is open.
Sensing edge not connected or
incorrectly connected.
Photocell FT1 not connected or
incorrectly connected.
Both limit switches in open con
tact state or not connected.
Door is at door open limit switch.
Door open limit switch absent or
not connected.
Door is at door closed limit
switch.
Door closed limit switch absent or
not connected.
Faulty contact or incorrect button
connection.
Faulty contact or incorrect button
connection.
Possible transmission fault or the
radio trasmission is activated.
N.B.: Press TEST button to exit from the TEST Mode.
50
ACTION BY SOFTWARE
Set the parameter
if not
used or to disable
Set the parameter
e
if not used or to disable
PHYSICAL CORRECTIVE ACTION
contact with the COM contact.
Jumper contact COS with contact COM, if not
used or to disable
Jumper contact FT1 with contact COM, if not
used or to disable. Check connection referring
Check connection of limit switches.
Check connection of limit switches.
Check connection of limit switches.
Check contact and connections to button.
Check contact and connections to button.
Make sure that no radio buttons are activated
wrongfully; remove and reconnect radio board
or replace with new board.