2.4.6.9.
PROFIBUS PLC Option (Harsh Enclosure)
The PROFIBUS PLC option board (Figure 2-55) is installed in position 3 (Figure 2-34) on the main
board. Connection to the PROFIBUS board in the harsh enclosure (Figure 2-55) is made using a
right-angle nine-pin connector inside the IND570 enclosure. This connector is a standard Siemens
part # 6ES7 972-0BA41-0XA0 or equivalent. It is not supplied by METTLER TOLEDO.
There are two nine-pin connectors on the PROFIBUS board – use the connector and cable routing
shown in Figure 2-56. Refer to Figure 2-54 for the PROFIBUS nine-pin connector assignments and
follow the wiring instructions included with the connector to terminate the wires.
30205319
|
04
|
08/2016
Pin
Signal
1
Not used
2
Not used
3
RxD/TxD +
4
RTS
5
GND bus
6
+5V bus
7
Not used
8
RxD/TxD -
9
Not used
Figure 2-54: PROFIBUS Nine-Pin Connector Assignments
Figure 2-55: PROFIBUS Option Board for Harsh Enclosure
METTLER TOLEDO IND570 Weighing Terminal Installation Manual
NOTES:
1. USE MATING CONNECTORS AND CABLE
RECOMMENDED FOR PROFIBUS
CONNECTIONS.
2. REFER TO PROFIBUS INTERNATIONAL
DOCUMENTATION FOR OTHER
CONSIDERATIONS.
2-37