Electromagnetic Fields & Interferences; Ip Protection Rating; Installation - voestalpine Bohler WF 330 ArcDrive Classic Instrucciones De Uso

Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 94
1.7 Electromagnetic fields &
interferences
• The welding current passing through the internal and external
system cables creates an electromagnetic field in the proxim-
ity of the welding cables and the equipment itself.
• Electromagnetic fields can affect the health of people who
are exposed to them for a long time (the exact effects are still
unknown).
Electromagnetic fields can interfere with some equipment like
pacemakers or hearing aids.
Persons fitted with pacemakers must consult their
doctor before undertaking arc welding or plasma
cutting operations.
EMC equipment classification in accordance with EN/IEC
60974-10 (See rating plate or technical data)
Class B equipment complies with electromagnetic compatibility
requirements in industrial and residential environments, includ-
ing residential locations where the electrical power is provided
by the public low-voltage supply system.
Class A equipment is not intended for use in residential locations
where the electrical power is provided by the public low-voltage
supply system. There may be potential difficulties in ensuring
electromagnetic compatibility of class A equipment in those
locations, due to conducted as well as radiated disturbances.
Installation, use and area examination
This equipment is manufactured in compliance with the
requirements of the EN60974-10 harmonized standard and is
identified as "CLASS A" equipment.
This unit must be used for professional applications only, in
industrial environments.
The manufacturer will accept no responsability for any damages
caused by use in domestic environments.
The user must be an expert in the activity and as such
is responsible for installation and use of the equip-
ment according to the manufacturer's instructions.
lf any electromagnetic interference is noticed, the
user must solve the problem, if necessary with the
manufacturer's technical assistance.
In any case electromagnetic interference problems
must be reduced until they are not a nuisance any
longer.
Before installing this apparatus, the user must evalu-
ate the potential electromagnetic problems that
may arise in the surrounding area, considering in
particular the health conditions of the persons in
the vicinity, for example of persons fitted with pace-
makers or hearing aids.
Welding cables
To minimise the effects of electromagnetic fields follow the fol-
lowing instructions:
- Where possible, collect and secure the earth and power
cables together.
- Never coil the welding cables around your body.
- Do not place your body in between the earth and power
cables (keep both on the same side).
- The cables must be kept as short as possible, positioned as
close as possible to each other and laid at or approximately
at ground level.
- Position the equipment at some distance from the welding
area.
- The cables must be kept away from any other cables.
Earthing connection
The earth connection of all the metal components in the welding
equipment and in the close aerea must be taken in consideration.
The earthing connection must be made according to the local
regulations.
Earthing the workpiece
When the workpiece is not earthed for electrical safety reasons
or due to its size and position, the earthing of the workpiece
may reduce the emissions. It is important to remember that
the earthing of the workpiece should neither increase the risk
of accidents for the user nor damage other electric equipment.
The earthing must be made according to the local regulations.
Shielding
The selective shielding of other cables and equipment present
in the surrounding area may reduce the problems due to elec-
tromagnetic interference. The shielding of the entire welding
equipment can be taken in considered for special applications.

1.8 IP Protection rating

S
IP23S
- Enclosure protected against access to dangerous parts by fin-
gers and against ingress of solid foreign bodies with diameter
greater than/equal to 12.5 mm
- Enclosure protected against rain at an angle of 60°.
- Enclosure protected against harmful effects due to the ingress
of water when the moving parts of the equipment are not
operating.

2 INSTALLATION

Installation should be performed only by expert
personnel authorised by the manufacturer.
During installation, ensure that the power source
is disconnected from the mains.
29
Tabla de contenido

Solución de problemas

loading

Este manual también es adecuado para:

Bohler wf 330 arcdrive smartBohler wf 330 rapideep steel

Tabla de contenido