Block 8: Charging settings
Parameter
Free charging
Free charging mode
Rfid Tag for Free Charging with
OCPP Full, fixed rfid modes
If in doubt allow charging
Block 9: Charging current
Parameter
Operator Current Limit (A)
Block 10: Dynamic load management (DLM)
Parameter
Description
Dynamic Load
Used to set the charge point function for load
Management
management in a DLM network
DLM Network Id
Setting that specifies which DLM network ID the
charge point is assigned to
DLM Master IP and
IP address of the DLM master that controls the
port
charging point. The port can also be specified
Disable Discovery
Setting that specifies whether Discovery
Broadcasting
Broadcasting is disabled on the DLM-Master
DLM Algorithm
Duration required to determine the algorithm
Sample Rate
Allow EV Wakeup
Setting that species whether to continue to provi-
de charging current after charging the vehicle
EVSE Sub-
Maximum mains current available for load
Distribution Limit
management
(L1/L2/L3) [A]
Operator EVSE
Upper current limit for load management. This
Sub-Distribution
value can be changed during operation (e.g. tem-
Limit (L1/L2/L3) [A]
porarily from Backend-System)
External Input 1
Config
Ext. Input 1 Current
Offset (L1/L2/L3) [A]
External Input 2
Config
26
Description
Charging without authorization. Charging
process begins as soon as a vehicle is
plugged in
Setting the OCPP behavior
RFID UID for the mode "Full fixed Rfid"
Emergency charging if no Backend-System
is connected
Description
Maximum charging current
Not relevant for the device
Not relevant for the device
Not relevant for the device
Necessary for ... Remark
Authorization
Necessary for ...
Charging sys-
tem
Necessary
Remark
for ...
Format: Any number between
0 and 255
For the assignment of static
IP addresses, this parameter
must be set to "On"
Charging
system
e.g. rated fuse current in the
power supply cable
This value is smaller than or
equals the value for "EVSE
Sub-Distribution Limit"
Only when "Free
charging" = "On"
Remark
Tabla de contenido