Maintenance Maintenance And Inspection - Hitachi NV 90AG Instrucciones Y Manual De Seguridad

Clavador
Tabla de contenido
Idiomas disponibles

Idiomas disponibles

NOTE: The information contained in this Manual is designed to assist you in the safe maintenance of the Nailer.
Some illustrations in this Manual may show details or attachments that diff er from those on your own Nailer.
MAINTENANCE AND INSPECTION
Read section titled "SAFETY" (pages 4 – 8).
● Disconnect air hose and remove all nails
from Nailer when:
1) doing maintenance and inspection; and
2) clearing a jam.
1. Clearing a jam
Remove a jammed nail in the following order:
1 DISCONNECT AIR HOSE.
2 Open the nail guide.
3 Insert a rod into the outlet.
Tap the rod with a hammer.
Hammer
Rod
Outlet
4 Remove the jammed nail with a slotted screw
driver.
Nail Slotted Screw Driver
5 Cut the deformed collated wire with nippers.
Correct the deformation.
MAINTENANCE
WARNING
1
Disconnect
air hose
6 In case of frequent jam, contact a Hitachi
authorized service center.
2. Inspecting the push lever
1 DISCONNECT AIR HOSE.
2 Clean the push lever sliding part.
Lubricate it with Hitachi pneumatic tool lubricant.
Lubricate
3. Inspecting the feeders
1 DISCONNECT AIR HOSE.
2 Clean the knob sliding part.
Lubricate it with Hitachi pneumatic tool lubricant.
Nail
Guide
Push Lever
Knob
3 Open the nail guide and remove dust.
Lubricate the sliding groove of the feeder and
shafts.
Nail
Stopper (A)
Nail Guide
Nail Stopper (B)
English
1
Disconnect
air hose
1
Disconnect
air hose
Feeder Shaft
Feeder
19
Tabla de contenido
loading

Este manual también es adecuado para:

Nv 90ags

Tabla de contenido