Recording
To release the security lock
While pressing SHIFT z, press REC/PLAY SPEED –.
The
indicator turns off.
Recording on the Same Cassette
Repeatedly — Repeat Recording
You can record on the same cassette repeatedly in two
different modes: MODE 1 and MODE 2.
REPEAT
r REC
REC
REPEAT
indicator
1
Press MENU until the OTHERS display appears
on the screen.
<
>
O T H E R S
R E P E A T
T A P E E N D
A L A R M M O D E
C L O G D E T E C T .
R S - 2 3 2 C
S - V H S
2
Press SHIFT $ to move the flashing to REPEAT
and set the mode to MODE 1 or MODE 2 by
pressing REC/PLAY SPEED +/–.
MODE 1: If an alarm input is received during
repeat recording, the recording mode switches to
alarm recording. After the end of the tape is
reached, the tape is automatically rewound and
stops at the beginning. The OFF indicator lights in
the display window.
MODE 2: If an alarm input is received during
repeat recording, the recording mode switches to
alarm recording. Repeat recording is performed
regardless of whether an alarm input is received or
not.
16
SHIFT z
REC/PLAY
SPEED –
MENU
REC/PLAY
SPEED +/–
SHIFT $
M O D E 1
- 3 M
Y
Y
1 2 0 0
Y
3
Set REPEAT REC to ON.
The REPEAT indicator lights.
4
Press r REC.
Recording begins.
When the tape reaches the end, the tape is rewound
at the beginning and recording resumes.
Note
If REPEAT REC is set to OFF while repeat recording
is in progress, recording proceeds until the end of the
tape is reached and then stops automatically after the
tape is rewound at the beginning. The OFF indicator
lights in the display window.
Series Recording
Connect another SVT-S3050P for series recording (for
details on connection, see page 9) and set each of the
units as follows.
Item
Unit #1
SERIES on ALARM
Y
SET screen
TAPE END on
–3M
OTHERS screen
Loaded
Cassette tape (E-180)
Operating status
Recording
OFF
REPEAT REC
Locked
Security lock
OFF
TIMER REC
When all of the settings are complete, set unit #1 in
recording mode and turn off the power of unit #2 and
subsequent unit.
When recording on unit #1 is complete, the power for
unit #2 turn on and recording begins (The recording
cannot be done for about 11 seconds.).
The unit #1 rewinds its tape and turns off.
When an E-180 tape is used and TAPE END is set to
–3M, the unit #2 starts recording before the unit #1
stops so that recording is continued without stop.
Unit #2
Unit #3 and
subsequent
unit
Y
Y
–3M
–3M
Loaded
Loaded
Turned off
Turned off
OFF
OFF
Locked
Locked
OFF
OFF