English
(1) Pilot lamp indication
The indications of the pilot lamp will be as shown in
Table 2, according to the condition of the charger or
the rechargeable battery.
Before
charging
While
The
charging
pilot
lamp
lights or
Charging
blinks in
complete
red.
Charging
impossible
The
Overheat
pilot lamp
standby
lights in
green.
(2) Regarding the temperature of the rechargeable
battery.
The temperatures for rechargeable batteries are as
shown in the Table 3, and batteries that have become
hot should be cooled for a while before being
recharged.
Table 3 Recharging ranges of batteries
Rechargeable
Temperatures at which the
batteries
battery can be recharged
BSL1830
(3) Regarding recharging time
Table 4
Charging time (At 68°F (20°C))
Charger
Battery
BSL1830
NOTE:
The charging time may vary according to
temperature and power source voltage.
4. Disconnect battery charger from the receptacle.
CAUTION
Do not pull the plug out of the receptacle by pulling
on the cord.
Make sure to grasp the plug when removing from
receptacle to avoid damaging cord.
12
01Eng_WH18DSDL_US.p65
Table 2
Indications of the pilot lamp
Lights for 0.5 seconds. Does not light for 0.5
seconds. (off for 0.5 seconds)
Blinks
Lights continuously
Lights
Lights for 0.5 seconds. Does not light for 0.5
seconds. (off for 0.5 seconds)
Blinks
Lights for 0.1 seconds. Does not light for 0.1
Flickers
seconds. (off for 0.1 seconds)
Lights continuously
Lights
32°F – 122°F
(0°C – 50°C)
UC18YRSL
Approx. 45 min.
12
5. Remove the battery from the battery charger.
Supporting the battery charger with hand, pull out
the battery from the battery charger.
How to make the batteries perform longer
(1) Recharge the batteries before they become
completely exhausted.
When you feel that the power of the tool becomes
weaker, stop using the tool and recharge its battery.
If you continue to use the tool and exhaust the
electric current, the battery may be damaged and
its life will become shorter.
(2) Avoid recharging at high temperatures.
A rechargeable battery will be hot immediately after
use. If such a battery is recharged immediately after
use, its internal chemical substance will deteriorate,
and the battery life will be shortened. Leave the
battery and recharge it after it has cooled for a while.
CAUTION
●
When the battery charger has been continuosly
used, the battery charger will be heated, thus
constituting the cause of the failures. Once the
charging has been completed, give 15 minutes rest
until the next charging.
●
If the battery is rechraged when it is warm due to
battery use or exposure to sunlight, the pilot lamp
may light in green.
The battery will not be recharged. In such a case,
let the battery cool before charging.
10/2/12, 2:38 PM
Malfunction in the
battery or the charger
Battery overheated.
Unable to charge
(Charging will commence
when battery cools).