7.4.3.2 RTC Mode 1 – Daily Interval
In this mode the output contacts will be activated every day in the programmed range.
The activation time is also programmable, choosing the time in which the output will be
turned on and off. It is necessary to enable the RTC block so that the output is turned on.
On CLIC-02 display or in the programming tool, the RTC block Mode 1 is displayed this way:
In the following example the output will be turned on from Monday to Friday, from 8:00
to 17:00.
Semana
Week
Time
Hora
Habilitação
Enabling
Output
Saída
② ④⑤
⑥⑧
Monday
Segunda
Tuesday Wednesday ...
Terça
8:00 17:00 8:00 17:00 8:00 17:00
8:00
17:00 8:00 17:00 8:00 17:00
- English -
Symbol
RTC number: R01 ~ R1F
RTC Mode: 1
Current RTC value of CLIC-02
Hour:Minute
Day of the week for operation start
Day of the week for operation end
Day hour to turn output on
Day minute to turn output on
Day hour to turn output off
Day minute to turn output off
⑨⑦
Quarta
...
Friday
Sexta
8:00 17:00
8:00 17:00
Ladder Logic Programming
Description
③
①
Saturday Sunday
Sábado
Domingo
CLIC-02 | 89