Special Maintenance Work - Dräger X-plore 6300 Instrucciones De Uso

Tabla de contenido
Idiomas disponibles

Idiomas disponibles

After carrying out the tests
 Remove the adaptor.
 Remove the mask from the test head and dry it if
necessary.
 Fit the exhalation valve cover in place.

Special maintenance work

The leak tests must be repeated after having carried out any
repair work and/or after replacing any parts.
Regular maintenance, repair and tests of the X-plore 6300
before use are very important to ensure safe usage of the full
face mask. As such, it is crucial that the test and mainte-
nance intervals are observed.
Replacing the visor
 Undo the screws. Place a flat head screw driver
between the edges of the lens frame and prise apart.
 Remove the support, see "Replacing the mask
connector".
 Remove the old visor from the rubber body.
 Fit in a new visor, first in the upper part and then the
lower part of the rubber body.
The markings on the visor must be lined up with the
seam of the mask body.
 Pull the rubber body above the edge of the visor to the
right and the left.
 Moisten the exterior of the rubber body and the interior
of the lens frame with a solution of soap and water.
 First fit the upper part of the visor in place followed by
the lower part.
 Insert the support.
 Insert and tighten the screw.
Replacing the mask connector
 Remove the inner mask from the groove of the
threaded ring.
 Use a flat head screw driver to
open the clip.
 Remove the clip, the slip ring
and the support.
 Remove the mask connector
from the mask body.
 Insert the speech diaphragm and the inhalation and
exhalation valves in the new mask connector mask and
adjust in such way that the markings on the new mask
connector and those on the mask body are properly
aligned.
 Mount the slip ring and the new clamp. Fit the catch in
such way as to allow maximum adjustment of the
clamp.
 Insert the support between the
clamp and the slip ring, then fit
the lower part of the lens frame
and align.
 Tighten the nose of the clamp
using R 53 239 pliers until the
mask connector is safely joined
to the mask body.
 Insert the inner mask.
Replacing the valve and inner mask discs
 Remove the old valve disc on the inside.
 Insert the pin of the new valve disc into the opening
from the inside, then pull them towards the visor until
the rear section of the pin is visible.
The valve discs must be adjusted evenly inside.
6
Replacing the speech diaphragm and the O-Ring
 Remove the inner mask from the groove of the
threaded ring.
 Loosen the threaded ring using the R 26 817 wrench.
 Turn the wrench, and insert it carefully in the openings
of the protection grating, being careful not to damage
the diaphragm.
 Turn the speech diaphragm to
loosen and remove it.
 Remove the O-ring from the
mask
connector
using
R 21 519 or 40 54 983 sealing
ring lifter. Test the speech
diaphragm and the
O-ring and replace them if necessary.
 Insert the inner mask.
Replacing the exhalation valve disc
 See "Visual Inspection of the exhalation valve" on
Page 5.
 Fit the exhalation valve cover in place.
Replacing the inhalation valve disc
 Pull out the inhalation valve from the side.
 Remove the old disc and replace it with a new one.
 Fit the inhalation valve in the mask connector so it
makes full contact. The valve disc must not be blocked
or clogged. The disc must point towards the inside and
the frame towards the outside.
Transport
Transport the full face mask in a carrying box or mask bag.
Storage
 Fully open the harness.
 Pack the full face mask in its bag or a storage box.
 Store in a dry cool place that is dust free so that it is not
damaged.
 Storage temperature: 5
 Do not expose to high temperatures and sunlight.
 Observe ISO 2230 "Rubber products - Storage
Instructions" and national directives on storage,
maintenance and cleaning of rubber products.
All Dräger rubber products are protected against premature
ageing. This protection agent sometimes becomes visible as
a grey white film. If this occurs, this film can be removed
using neutral soap and a brush.
Disposal
Dispose of the full face mask in accordance with the applica-
ble local waste disposal regulations.
an
o
o
o
o
F to 77
F/-15
C to 25
C.
Tabla de contenido
loading