KENMORE ELITE W10168300A Manual De Uso Y Cuidado página 29

Tabla de contenido
Idiomas disponibles

Idiomas disponibles

Model P1KB2/P1RFKB2 Capacity 200 Gallons (757 Liters) without Filter Indicator Light
This system has been tested according to NSF/ANSI Standards 42 and 53 for the reduction of the substances listed below. The
concentration of the indicated substances in water entering the system was reduced to a concentration less than or equal to the
permissible limit for water leaving the system, as specified in NSF/ANSI Standards 42 and 53.
Substance Reduction
NSF Reduction
Aesthetic Effects
Requirements
Chlorine Taste/Odor
50% reduction
*
Particulate Class I
85% reduction
Contaminant
NSF Reduction
Reduction
Requirements
Lead: @ pH 6.5
0.010 mg/L
Lead: @ pH 8.5
0.010 mg/L
Mercury: @ pH 6.5
0.002 mg/L
Mercury: @ pH 8.5
0.002 mg/L
Benzene
0.005 mg/L
O-Dichlorobenzene
0.6 mg/L
Toxaphene
0.003 mg/L
Atrazine
0.003 mg/L
Asbestos
99%
Live Cysts
>99.95%
Turbidity
0.5 NTU
Alachlor
0.002 mg/L
Endrin
0.002 mg/L
Ethylbenzene
0.7 mg/L
Lindane
0.0002 mg/L
Chlorobenzene
0.1 mg/L
Tetrachloroethylene
0.005 mg/L
Styrene
0.1 mg/L
Test Parameters: pH = 7.5 ± 0.5 unless otherwise noted. Flow = 0.5 gpm (1.9 Lpm). Pressure = 60 psig (413.7 kPa).
Temp. = 68°F to 71.6°F (20°C to 22°C). Rated service capacity = 200 gallons (757 liters).
It is essential that operational, maintenance, and filter
replacement requirements be carried out for the product to
perform as advertised.
Model P1KB2: Change the water filter cartridge every 6 months.
If the water flow to the water dispenser or ice maker decreases
noticeably before 6 months have passed, replace the water filter
cartridge more often.
Use replacement cartridge P1RFKB2, part #9030.
2008 suggested retail price of $59.99 U.S.A./$71.99 Canada.
Prices are subject to change without notice.
These contaminants are not necessarily in your water supply.
While testing was performed under standard laboratory
conditions, actual performance may vary.
The product is for cold water use only.
*
Class I particle size: >0.5 to <1 um
**
Test requirement is at least 100,000 particles/mL of AC Fine Test Dust.
††
Fibers greater than 10 um in length
Based on the use of Cryptosporidium parvum oocysts
® NSF is a registered trademark of NSF International.
All manuals and user guides at all-guides.com
Base Grille Water Filtration System
System tested and certified by NSF International against NSF/ANSI Standard 42 for the reduction of
Chlorine Taste and Odor, Particulate Class I*; and against NSF/ANSI Standard 53 for the reduction of
Lead, Mercury, Atrazine, Benzene, Toxaphene, O-Dichlorobenzene, Cysts, Turbidity, Asbestos,
Lindane, Tetrachloroethylene, Endrin, Alachlor, Styrene, Chlorobenzene and Ethylbenzene.
Average
Influent
2.10 mg/L
21000000#/mL
Average
Influent
150 ug/L
160 ug/L
5.8 ug/L
6.1 ug/L
15 ug/L
1900 ug/L
14 ug/L
9.0 ug/L
130 MFL
96,000/L
12 NTU
41 ug/L
5.9 ug/L
2100 ug/L
1.9 ug/L
2100 ug/L
14 ug/L
2200 ug/L
Influent Challenge
Maximum
Concentration
Effluent
2.0 mg/L ± 10%
0.05 mg/L
At least 10,000 particles/mL
140000 #/mL
Influent Challenge
Maximum
Concentration
Effluent
0.15 mg/L ± 10%
1.0 ug/L
0.15 mg/L ± 10%
2.0 ug/L
0.006 mg/L ± 10%
0.3 ug/L
0.006 mg/L ± 10%
0.4 ug/L
0.015 mg/L ± 10%
0.5 ug/L
1.8 mg/L ± 10%
0.7 ug/L
0.015 mg/L ± 10%
1.0 ug/L
0.009 mg/L ± 10%
0.5 ug/L
10
7
to 10
8
fibers/L
††
0.17 MFL
50,000/L min.
1/L
11 ± 1 NTU
0.4 NTU
0.04 mg/L ± 10%
1.0 ug/L
0.006 mg/L ± 10%
0.2 ug/L
2.1 mg/L ± 10%
0.5 ug/L
0.002 mg/L ± 10%
0.02 ug/L
2.0 mg/L ± 10%
1.1 ug/L
0.015 mg/L ± 10%
0.5 ug/L
2.0 mg/L ± 10%
ND (0.5)
Do not use with water that is microbiologically unsafe or of
unknown quality without adequate disinfection before or after the
system. Systems certified for cyst reduction may be used on
disinfected waters that may contain filterable cysts.
Refer to the "Warranty" section for the Manufacturer's name,
address and telephone number.
Refer to the "Warranty" section for the Manufacturer's limited
warranty.
Application Guidelines/Water Supply Parameters
Water Supply
Water Pressure
Water Temperature
Service Flow Rate
Minimum %
Reduction
97.6
**
99
Minimum %
Reduction
99.3
98.7
94.9
93.4
96.7
99.9
91.5
94.5
99
99.99
96.7
97.6
96.5
99.9
99
99.9
96
99.9
City or Well
30 - 120 psi (207 - 827 kPa)
33° - 100°F (0.6° - 37.8°C)
0.5 gpm (1.9 L/min) @ 60 psi
Average %
Reduction
97.6
99.5
Average %
Reduction
99.3
99.3
96.6
95.3
96.7
99.9
92.8
94.5
99
99.99
98.5
97.6
96.6
99.9
99
99.9
96.4
99.9
29
Tabla de contenido

Solución de problemas

loading

Tabla de contenido