KENMORE ELITE W10168300A Manual De Uso Y Cuidado página 28

Tabla de contenido
Idiomas disponibles

Idiomas disponibles

This system has been tested according to NSF/ANSI Standards 42 and 53 for the reduction of the substances listed below. The
concentration of the indicated substances in water entering the system was reduced to a concentration less than or equal to the
permissible limit for water leaving the system, as specified in NSF/ANSI Standards 42 and 53.
Substance Reduction
NSF Reduction
Aesthetic Effects
Requirements
Chlorine Taste/Odor
50% reduction
*
Particulate Class I
85% reduction
Contaminant
NSF Reduction
Reduction
Requirements
Lead: @ pH 6.5
0.010 mg/L
Lead: @ pH 8.5
0.010 mg/L
Mercury: @ pH 6.5
0.002 mg/L
Mercury: @ pH 8.5
0.002 mg/L
Benzene
0.005 mg/L
O-Dichlorobenzene
0.6 mg/L
Toxaphene
0.003 mg/L
Atrazine
0.003 mg/L
Asbestos
99%
Live Cysts
>99.95%
Turbidity
0.5 NTU
Alachlor
0.002 mg/L
Endrin
0.002 mg/L
Ethylbenzene
0.7 mg/L
Lindane
0.002 mg/L
Chlorobenzene
0.6 mg/L
Tetrachloroethylene
0.005 mg/L
TTHM
0.080 mg/L
MTBE
0.005 mg/L
VOC
0.015 mg/L
Test Parameters: pH = 7.5 ± 0.5 unless otherwise noted. Flow = 0.5 gpm (1.9 Lpm). Pressure = 60 psig (413.7 kPa).
Temp. = 68°F to 71.6°F (20°C to 22°C). Rated service capacity = 100 gallons (379 liters).
It is essential that operational, maintenance, and filter
replacement requirements be carried out for the product to
perform as advertised.
Model T1KB1: The filter monitor system measures the amount of
water that passes through the filter and alerts you to replace the
filter.
Style 1 - When the filter indicator reads 10%, order a new filter.
When the indicator reads 0%, it is recommended that you
replace the filter.
Style 2 - When the filter indicator changes from green to yellow,
order a new filter. When the indicator changes from yellow to red,
it is recommended that you replace the filter.
Style 3 - When the water filter status display changes from
"GOOD" to "ORDER," order a new filter. When the filter indicator
reads "REPLACE," it is recommended that you replace the filter.
Use replacement cartridge T1RFKB1, part #9030.
2008 suggested retail price of $59.99 U.S.A./$71.99 Canada.
Prices are subject to change without notice.
These contaminants are not necessarily in your water supply.
While testing was performed under standard laboratory
conditions, actual performance may vary.
The product is for cold water use only.
*
Class I particle size: >0.5 to <1 um
**
Test requirement is at least 100,000 particles/mL of AC Fine Test Dust.
††
Fibers greater than 10 um in length
Based on the use of Cryptosporidium parvum oocysts
® NSF is a registered trademark of NSF International.
28
All manuals and user guides at all-guides.com
Base Grille Water Filtration System
Model T1KB1/T1RFKB1 Capacity 100 Gallons (379 Liters)
System tested and certified by NSF International against NSF/ANSI Standard 42 for the reduction of
Chlorine Taste and Odor, Particulate Class I*; and against NSF/ANSI Standard 53 for the reduction of
Lead, Mercury, Atrazine, Benzene, Toxaphene, O-Dichlorobenzene, Cysts, Turbidity, Asbestos, Lindane,
Tetrachloroethylene, Endrin, Alachlor, Chlorobenzene, Ethylbenzene, TTHM, MTBE and VOC.
Average
Influent Challenge
Influent
Concentration
2.0 mg/L
2.0 mg/L ± 10%
3533333#/mL
At least 10,000 particles/mL
Average
Influent Challenge
Influent
Concentration
150 ug/L
0.15 mg/L ± 10%
157 ug/L
0.15 mg/L ± 10%
0.0058 mg/L
0.006 mg/L ± 10%
0.0057 mg/L
0.006 mg/L ± 10%
15 ug/L
0.015 mg/L ± 10%
1750 ug/L
1.8 ± 10%
15 ug/L
0.015 ± 10%
10 ug/L
0.009 mg/L ± 10%
101 MFL
10
120,000/L
50,000/L min.
11.4 NTU
11 ± 1 NTU
41.3 ug/L
0.04 ± 10%
5.9 ug/L
0.006 ± 10%
1867 ug/L
2.1 ± 10%
1.9 ug/L
0.002 ± 10%
2.0 ug/L
2.0 ± 10%
14.2 ug/L
0.015 ± 10%
465 ug/L
0.45 ± 20%
14 ug/L
0.015 ± 20%
0.3520 mg/L
0.300 ± 10%
Maximum
Effluent
0.08 mg/L
22000 #/mL
Maximum
Effluent
1.0 ug/L
2.0 ug/L
0.0002 mg/L
0.0002 mg/L
0.5 ug/L
1.0 ug/L
1.0 ug/L
2 ug/L
7
8
††
to 10
fibers/L
0.17 MFL
8/L
0.41 NTU
0.2 ug/L
0.5 ug/L
0.70 ug/L
0.02 ug/L
0.0005 ug/L
0.5 ug/L
1.0 ug/L
0.70 ug/L
0.0060 mg/L
Do not use with water that is microbiologically unsafe or of
unknown quality without adequate disinfection before or after the
system. Systems certified for cyst reduction may be used on
disinfected waters that may contain filterable cysts.
Refer to the "Warranty" section for the Manufacturer's name,
address and telephone number.
Refer to the "Warranty" section for the Manufacturer's limited
warranty.
Application Guidelines/Water Supply Parameters
Water Supply
Water Pressure
Water Temperature
Service Flow Rate
Average
Minimum %
Effluent
Reduction
2.0 mg/L
95.93
**
11567 #/mL
99.38
Average
Minimum %
Effluent
Reduction
1 ug/L
99.33
1.08 ug/L
98.72
0.0002 mg/L
96.53
0.0002 mg/L
96.5
0.5 ug/L
96.67
1.0 ug/L
99.94
1.0 ug/L
93.33
2 ug/L
80.8
0.17 MFL
99.83
1/L
99.99
0.24 NTU
96.4
0.2 ug/L
99.52
0.3 ug/L
91.5
0.0588 ug/L
99.96
0.02 ug/L
98.93
0.0005 ug/L
99.98
0.5 ug/L
96.47
0.5 ug/L
99.78
0.52 ug/L
94.94
0.0008 mg/L
98.4
City or Well
30 - 120 psi (207 - 827 kPa)
33° - 100°F (0.6° - 37.8°C)
0.5 gpm (1.9 L/min) @ 60 psi
Average %
Reduction
97.36
99.67
Average %
Reduction
99.33
99.31
96.53
96.5
96.67
99.94
93.33
80.8
99.83
>99.99
97.89
99.52
95.47
100
98.93
99.98
96.47
99.88
96.27
99.78
Tabla de contenido

Solución de problemas

loading

Tabla de contenido