• In Step 4 – Summary, review all parameter settings. Return to any step to make required
changes, and click Apply.
• The Quick Start is now complete. Put Resource Block into Automatic Mode (see
ing Block Modes
Maintenance
SITRANS LR560 requires no maintenance or cleaning under normal operating conditions. If
cleaning becomes necessary:
1)
Note the antenna material and the process medium, and select a cleaning solution that
will not react adversely with either.
2)
Remove the device from service and wipe the antenna clean using a cloth and suitable
cleaning solution.
Unit Repair and Excluded Liability
For detailed information, please see the inside back cover.
Temperature De-Rating Curve
standard
version
Process Temperature (°C)
Never attempt to loosen, remove or disassemble process
WARNING:
connection or instrument housing while vessel contents are under pressure.
Page EN-20
SITRANS LR560 (FF) – QUICK START MANUAL
on page 18).
high
temperature
version
Chang-