Kärcher SB MU Manual Del Usuario página 69

Ocultar thumbs Ver también para SB MU:
Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

Fault
Possible cause
All coin acceptors
Main switch is switched off.
reject all coins
Incorrectly adjusted time of day or operating
times. Night operation lock active
Motor protection switch of the high pressure
pumps was triggered
A single coin ac-
Coin acceptor dirty
ceptor rejects all
coins
Overcurrent on the high pressure pump
Fault
Possible cause
Irregular water jet
High-pressure nozzle clogged
on the hand spray
Amount of water supply is too low.
gun
Suction hose kinked
Reduced pres-
High-pressure nozzle flushed
sure at the high-
Incorrect high pressure nozzle installed.
pressure pump
Amount of water supply is too low.
Pressure does
High-pressure hose to the washdown yard
not build up in the
leaking
pump
Overflow valve misadjusted or leaking
The high pressure pump sucks air from the
empty detergent tank
High pressure
High pressure pump is sucking in air.
pump is knock-
ing; manometer is
swaying wildly
Vibration dampener is defective
Valve in pump head defective or contaminat-
ed.
The pump does
Overcurrent on the high pressure pump
not run
Fault
Possible cause
Inadequate or no
Filter or hose is blocked
flow of detergent
Leaky detergent hose
Dosing pump incorrectly adjusted or defec-
tive.
Dosing pump obstructed by condensate.
Malfunctions at coin mechanism
Remedy
Set main switch to "1".
Check the adjustments on the control.
Reset motor protection switch.
Determine the cause if it reoccurs.
Clean the coin acceptor (see section „Mainte-
nance work")
Acknowledge the fault on the control.
Faults on high pressure pumps
Remedy
Clean high-pressure nozzle.
Check water supply level (refer to technical da-
ta).
Check suction hose.
Replace the high-pressure nozzle.
Check/replace high-pressure nozzle.
Check water supply level (refer to technical da-
ta).
Check flushing solenoid valve,swimmer valve
and water quality solenoid valve.
Check the high-pressure line, replace if neces-
sary.
Check and repair the overflow valve.
Refill detergent. Bleed the suction line (to speed
up the bleeding process briefly squeeze the suc-
tion hose to the pump repeatedly during opera-
tion).
Check suction pipes for water and detergent and
ensure that they are leak-proof.
Detergent container empty? (see above)
Replace vibration dampener.
Replace defective valves.
Acknowledge the fault on the control.
Disturbed detergent supply
Remedy
Clean the parts.
Replace the hose
Check the dosing pump and the setting.
Drain the condensate from the pressure contain-
er of the compressor.
31
-
EN
By whom
Operator
Operator
Operator
Operator
Operator
By whom
Operator
Operator
Operator
Operator
Operator
Operator
Customer Ser-
vice
Operator, Cus-
tomer Service
Customer Ser-
vice
Operator
Operator
Operator
Operator
Customer Ser-
vice
Operator
By whom
Operator
Operator
Operator, Cus-
tomer Service
Customer Ser-
vice
69