Technical Date; General Description - Steinberg Systems SBS-DM-1000NCV Manual De Instrucciones

Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 17
U S E R M A N U A L

TECHNICAL DATE

Parameter description
Parameter value
Product name
Multimeter
Model
SBS-DM-1000NCV
Battery type
9V (6F22)/ NEDA 1604
Protection rating IP
CAT III 1000V
Over Voltage Protection
200mV~1000V/ 2V~750V
Measuring range of direct/
2mA~20A/2mA~20A
alternating current voltage
Measuring range of
200Ω~20MΩ/
direct/alternating current
2nF~200uF
amperage
Measuring range of
-20~1000°C/200kHz
electrical resistance/
capacitance

1. GENERAL DESCRIPTION

The user manual is designed to assist in the safe and
trouble-free use of the device. The product is designed
and manufactured in accordance with strict technical
guidelines,
using
state-of-the-art
technologies
components. Additionally, it is produced in compliance
with the most stringent quality standards.
DO NOT USE THE DEVICE UNLESS YOU HAVE
THOROUGHLY READ AND UNDERSTOOD THIS
EN
USER MANUAL.
To increase the product life of the device and to ensure
trouble-free operation, use it in accordance with this user
manual and regularly perform maintenance tasks. The
technical data and specifications in this user manual are
up to date. The manufacturer reserves the right to make
changes associated with quality improvement.
LEGEND
The product satisfies the relevant safety
standards.
Read instructions before use.
The product must be recycled.
WARNING! or CAUTION! or REMEMBER!
Applicable to the given situation. (general
warning sign)
ATTENTION! Electric shock warning!
Class II protection device with double
insulation.
PLEASE NOTE! Drawings in this manual are for
illustration purposes only and in some details may
differ from the actual product.
The original operation manual is written in German. Other
language versions are translations from the German.
2. USAGE SAFETY
ATTENTION! Read all safety warnings and all
instructions. Failure to follow the warnings and
instructions may result in electric shock, fire and/or
serious injury or even death.
The terms "device" or "product" are used in the warnings
and instructions to refer to < Multimeter >. Do not use in
very humid environments or in the direct vicinity of water
tanks. Prevent the device from getting wet. Risk of electric
shock! Do not cover the ventilation openings!
2.1. ELECTRICAL SAFETY
a)
The plug must fit the socket. Do not modify the
plug in any way. Using original plugs and matching
sockets reduces the risk of electric shock.
b)
Avoid touching earthed elements such as pipes,
heaters, boilers and refrigerators. There is an
increased risk of electric shock if the earthed device
is exposed to rain, comes into direct contact with a
wet surface or is operating in a damp environment.
Water getting into the device increases the risk of
damage to the device and of electric shock.
c)
Do not touch the device with wet or damp hands.
d)
Use the cable only for its designated use. Never use it
to carry the device or to pull the plug out of a socket.
Keep the cable away from heat sources, oil, sharp
edges or moving parts. Damaged or tangled cables
increase the risk of electric shock.
e)
If using the device in a damp environment cannot
be avoided, a residual current device (RCD) should
be applied. The use of an RCD reduces the risk of
electric shock.
and
2.2. SAFETY IN THE WORKPLACE
a)
Make sure the workplace is clean and well lit. A
messy or poorly lit workplace may lead to accidents.
Try to think ahead, observe what is going on and use
common sense when working with the device.
b)
Do not use the device in a potentially explosive
environment, for example in the presence of
flammable liquids, gases or dust. The device
generates sparks which may ignite dust or fumes.
c)
If you discover damage or irregular operation,
immediately switch the device off and report it to a
supervisor without delay.
d)
If there are any doubts as to the correct operation
of the device, contact the manufacturer's support
service.
e)
Only the manufacturer's service point may repair the
device. Do not attempt any repairs independently!
f)
In case of fire, use a powder or carbon dioxide
(CO
) fire extinguisher (one intended for use on live
2
electrical devices) to put it out.
g)
Children or unauthorised persons are forbidden to
enter a work station. (A distraction may result in loss
of control over the device)
h)
Regularly inspect the condition of the safety labels. If
the labels are illegible, they must be replaced.
i)
Please keep this manual available for future
reference. If this device is passed on to a third party,
the manual must be passed on with it.
REMEMBER! When using the device, protect
children and other bystanders.
2.3. PERSONAL SAFETY
a)
Do not use the device when tired, ill or under the
influence of alcohol, narcotics or medication which
can significantly impair the ability to operate the
device.
b)
The device is not designed to be handled by persons
(including children) with limited mental and sensory
functions or persons lacking relevant experience
8
and/or knowledge unless they are supervised by
a person responsible for their safety or they have
received instruction on how to operate the device.
c)
When working with the device, use common sense
and stay alert. Temporary loss of concentration while
using the device may lead to serious injuries.
d)
To prevent the device from accidentally switching on,
make sure the switch is on the OFF position before
connecting to a power source.
e)
The device is not a toy. Children must be supervised
to ensure that they do not play with the device.
2.4. SAFE DEVICE USE
a)
Do not use the device if the ON/OFF switch does not
function properly (does not switch the device on and
off). Devices which cannot be switched on and off
using the ON/OFF switch are hazardous, should not
be operated and must be repaired.
b)
When not in use, store in a safe place, away from
children and people not familiar with the device who
have not read the user manual. The device may pose
a hazard in the hands of inexperienced users.
c)
Keep the device in perfect technical condition.
d)
Keep the device out of the reach of children.
e)
Device repair or maintenance should be carried out
by qualified persons, only using original spare parts.
This will ensure safe use.
f)
To ensure the operational integrity of the device, do
not remove factory-fitted guards and do not loosen
any screws.
g)
Do not move, adjust or rotate the device in the
course of work.
h)
Do not leave this appliance unattended while it is in
use.
i)
Clean the device regularly to prevent stubborn grime
from accumulating.
j)
The device is not a toy. Cleaning and maintenance
may not be carried out by children without
supervision by an adult person.
k)
Never measure the voltage when the test leads are
connected to the amperage measurement sockets.
l)
Exercise caution when working with voltages above
DC60V or AC42V.
m)
During measurement, hold the test leads or probes
by the insulated parts.
n)
Select the appropriate function and measurement
to avoid damage to the multimeter during the
measurement.
o)
Disconnect the test leads from the test points before
switching to another function.
ATTENTION! Despite the safe design of the device
and its protective features, and despite the use of
additional elements protecting the operator, there is
still a slight risk of accident or injury when using the
device. Stay alert and use common sense when using
the device.
3. USE GUIDELINE
Multimeter is used to measure the electrical values of
selected devices and electrical circuits.
The user is liable for any damage resulting from
unintended use of the device.
3.1. DEVICE DESCRIPTION
ATTENTION! This product's exploded view can be
found on the last pages of the operating instructions
(pp. 38).
1.
Voltage detector (NCV)
2.
CDS sensor
3.
Red LED: voltage detection
4.
Green LED: voltage detection
5.
LCD display
6.
POWER button, turns the device on / off.
7.
D.HOLD button/Backlight: Lock/unlock the displayed
value
8.
NCV button enables (green lamp) or disables
contactless measurement mode
9.
Knob: selecting the function and measuring range.
10.
Input socket: mA T +, used for reading the capacitor
, mA and temperature "+" .
11.
Input socket: 20A.
12.
Input socket: Ω VΩHz: V / 200kHz.
13.
Input socket: T COMT-: COM and temperature "-".
14.
Input socket: hFE
3.2. PREPARING FOR USE
The ambient temperature should be between 18°C and
28°C (64°F to 82°F), and the relative humidity should not
exceed 70. Ensure good ventilation in the room in which
the device is being used. There should be at least 10 cm
distance between each side of the device and the wall or
other objects. Keep the device away from hot surfaces.
Operate the device on an even, stable, clean, fire-proof and
dry surface and out of the reach of children and persons
with mental disabilities. Position the device such that you
always have access to the power plug. The power cord
connected to the appliance must be properly grounded
and correspond to the technical details on the product
label!
3.3. WORKING WITH THE DEVICE
PLEASE NOTE: The symbol
and the description next
to the input sockets stands for voltage and current levels
which can not be exceeded as it may cause loss of life or
damage to health and impair the multimeter.
PLEASE NOTE: Before starting the measurement make sure
that the function selection and measurement range dial is
set to the correct range
PLEASE NOTE: If you are not sure about the scale of the
measured current, set the range switch to the top position
PLEASE NOTE: If numbers 1 or -1 are shown on the display,
the measured value is out of the selected range scale.
Increase the measuring range and try again.
PLEASE NOTE: If the device displays the low battery
message, the battery needs to be replaced.
3.3.1. DC VOLTAGE MEASUREMENT
a)
Turn the dial to V "
b)
Connect the black test lead to the COMT terminal
and the red test lead to the VΩHz terminal.
c)
Hook the measuring probes to the tested circuit
d)
The measured value will be displayed on the LCD
screen. The polarity of the red lead will be indicated,
and the DC voltage value.
3.3.2. AC VOLTAGE MEASUREMENT
a)
Turn the dial to V~.
b)
Connect the black test lead to the COMT terminal
and the red test lead to the VΩHz terminal.
c)
Touch the tested circuit with both probes
d)
The measured value will be displayed on the LCD
screen.
9
EN
Tabla de contenido
loading

Tabla de contenido