lift the batteries from the compartment using suitable lifting equipment.
The battery-charger
Never let the batteries run down excessively, as they could become damaged irreparably.
Before charging the batteries, check that the main switch on the control panel is in the "0"
Choosing the battery-charger
Check that the battery-charger is compatible with the batteries to be charged:
tubular lead batteries: an automatic battery-charger 24V - 20A is suggested. Anyway,
►
refer to the Manufacturer and read the relative manual to confirm your choice;
►
gel batteries: use a battery-charger specifically intended for this type of storage batteries.
Preparing the battery-charger
If you wish to use a battery-charger not supplied with the machine, it is necessary to mount on it the
connector delivered with the machine (see paragraph "Unpacking" of this manual).
To install the connector proceed as follows:
►
remove about 13 mm of sheath from the black and red cables of the battery-charger;
►
insert the cables in the connector pins and push strongly with suitable pliers;
►
insert the cables in the connector respecting the polarity (red cable +, black cable –).
Lifting and handling the machine
All
stages
quately lighted environment adopting all necessary safety measures.
Always wear individual protections for the user's safety.
The loading of the machine onto a vehicle must be done as follows:
►
empty the recovery tank and the solution tank;
►
remove the squeegee and the brushes (or drive discs);
►
remove the batteries;
►
place the machine on the pallet, engage the parking brake and secure it with plastic straps
or metal brackets;
►
lift the pallet by means of a fork lift truck and load it on the vehicle;
►
anchor the machine to the vehicle with ropes connected to the pallet and to the chassis of
the machine.
PRACTICAL GUIDE FOR THE USER
Control devices - Description
With reference to fig. 8 the machine has the following controls and leds:
►
Battery charge level indicator (ref. 9): signals both "Power on" and the battery charge
level. Note: the following percentages are based on the usable capacity and not the total
capacity of the batteries (therefore 100% flat = 80% of total battery capacity). Possible
situations are:
►
off: the main switch is set to "0" (off) or the batteries are disconnected;
►
green light: batteries charged from 100% to 50%;
►
yellow light: batteries charged from 50% to 15%;
WARNING
WARNING
(off) position.
WARNING
must
be
GB
performed
in
an
ade-
19