Initial Testing; Start-Up - Roger Technology H70/104AC Instrucciones Y Advertencias Para El Instalador

Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 135
Warning! Do not use any controls until the gate has completed the opening and
closing manoeuvre.
Position recovery is performed immediately when the limit switches (if installed)
are activated.
19

Initial testing

The installer is required to measure impact forces and select on the control
unit the appropriate speed and torque
values to ensure that the motorised door or gate remains within the limits
in Chapter 1 "GENERIC WARNINGS are observed.
• Turn on the power supply.
• Check that all connected controls are working correctly.
• Check travel and deceleration.
• Check that the safety devices are activated correctly
• Disconnect from mains power then reconnect. Check that the position
recovery procedure is completed correctly.
• Check the limit switch settings (if installed).
• Check that the release system works correctly (H70/104AC only).
20

Start-up

instructions manual of each device and / or accessory and the system's
maintenance plan.
Apply a plate indicating the automation system data on the motorised door or
Apply a plate and / or label with the indications for the operations required to
manually unlock the system.
and warnings for use and the
maintenance plan.
emergency operation of the system.
Inform the end user about the dangers and risks that may be present.