Enabled. The gate brakes before inverting direction when the control unit receives a close command
Set braking time
WARNING: check carefully that the chosen value is appropriate to the model of motor used.
Settable from 1 to 20 tenths of a second.
Set braking force
WARNING: preferably set low values to ensure that the gate stops correctly.
= minimum force ... = maximum force.
Selecting installation position of motor relative to gate (seen from interior side)
Motor installed on left.
Motor installed on right.
Enable limit switches
N.B.:
off then reconnect to mains power. Repeat acquisition procedure.
No limit switch installed.
Gate open and close limit switches installed.
Gate open limit switches installed.
Sensing edge NOT INSTALLED.
NC contact (normally closed). The gate reverses only when opening.
Contact with 8k2 resistor. The gate reverses only when opening.
NC contact (normally closed). The gate always reverses.
Contact with 8k2 resistor. The gate always reverses.
Sensing edge NOT INSTALLED.
NC contact (normally closed). The gate reverses only when closing.
Contact with 8k2 resistor. The gate reverses only when closing.
NC contact (normally closed). The gate always reverses.
Contact with 8k2 resistor. The gate always reverses.
N.B.:
then reconnect to mains power. Repeat acquisition procedure.
No encoder installed.
Optical encoders installed (8 pulses/revolution).
Magnetic encoders installed (1 pulse/revolution). Only the E30 series uses magnetic encoders.
STEP MODE.
PARTIAL OPENING
OPENING
CLOSING.
STOP.
66
COS1
COS2