START
5. Push the "START" button on the remote
control and hold on. Release the button when the
indicator light become off.
1.Unscrew the air cleaner cover by provided screwdriver.
6. The remote control is programmed to generator
successfully.

Remote Control Power Consumption

While the Engine Switch is in the "RUN" (I) position
and the battery power restore switch has been
pressed for about 3 seconds, the remote module is
active and waiting for signal. This function requires
electrical current which is consuming the battery.
THIS GENERATOR WILL AUTOMATICALLY
DISCONNECT THE BATTERY AFTER 12 HOURS
TO AVOID BATTERY DRAINAGE, IF THE
NOT RUNNING AND THE ENGINE
SWITCH IS LEFT IN "RUN" (I) POSITION.
YOU MUST GO THROUGH STARTING PROCEDURE
TO RESUME RUNNING THE UNIT AGAIN.

SPECIFICATIONS

Model
Starting Watts
Running Watts
English
10

Battery Cable Connection

Follow below instruction to connect battery to the
generator:
2. Cut wire tie that is binding the black battery
3. Insert the male connector of cable A into
female connector of cable B.
4. Reattach the air cleaner cover.
W03383
3650
3300