Functional Description - Black and Decker BDEDR3C Manual De Instrucciones

Tabla de contenido
Idiomas disponibles

Idiomas disponibles

warning:
cause serious and permanent respiratory or other injury. Always use NIOSH/
OSHA approved respiratory protection appropriate for the dust exposure. Direct
particles away from face and body.
• wear appropriate hearing protection during use. Under some conditions and
duration of use, noise from this product may contribute to hearing loss.
warning:
glasses. also use face or dust mask if cutting operation is dusty.
always wear certified safety eQuipMent:
• ANSI Z87.1 eye protection (CAN/CPA Z94.3),
• ANSI S12.6 (S3.19) hearing protection,
• NOSH/OSHA respiratory protection.
syMbols
The label on your tool may include the following symbols. The symbols and their definitions are as
follows:
V ..................volts
Hz ................hertz
min ..............minutes
or DC ...direct current
................Class I Construction
(grounded)
................Class II Construction
(double insulated)
............Read instruction manual before use
................Use proper eye protection
When using an extension
cord, be sure to use one heavy
enough to carry the current
your product will draw. An
undersized cord will cause a
drop in line voltage resulting in
loss of power and overheating.
The following table shows the
correct size to use depending
on cord length and nameplate
ampere rating. If in doubt, use
the next heavier gage. The
smaller the gage number, the
heavier the cord.

functional description

1. Variable speed trigger
2. Forward/reverse button
3. Chuck
4. Belt clip
5. Lock-on button
use of this tool can generate and/or disperse dust, which may
always use safety glasses. everyday eye glasses are not safety
volts
120V
240V
(0-15,2m) (15,2-30,4m) (30,4-60,9m) (60,9-91,4m)
ampere rating
More Not more
Than Than
0 -
6 -
10 -
12 -
A ...................amperes
W ..................watts
or AC .......alternating current
n o .................no load speed
.................earthing terminal
................safety alert symbol
.../min or rpm...revolutions or
reciprocations per minute
....................Use proper respiratory protection
.................Use proper hearing protection
Minimum gage for cord sets
total length of cord in feet
0-25
26-50
(0-7,6m) (7,6-15,2m) (15,2-30,4m) (30,4-45,7m)
0-50
51-100
American Wire Gage
6
18
16
10
18
16
12
16
16
16
14
12
3
4
51-100
101-150
101-200
201-300
16
14
14
Not Recommended
4
2
1
14
12
12
5
Tabla de contenido
loading

Tabla de contenido