8
Technical Data
EN
Working Voltage:
Permissible mains voltage:
Mains frequency:
Suction turbine power *):
Network input protection:
LpA **) (at max. volume flow):
Ø Suction fitting:
- inside
Flow rate, max�:
Negative pressure, max�:
Fine filter:
- Filter surface, approx�
- Filter quality
Filling volume dust drawer approx�:
Weight (empty), approx�:
Dimensions (width x height x depth):
CAM interface:
Input signal:
- Low
- High
Output signal:
- max� pull-up voltage
- max� switching current (I)
- internal series resistor
*) At nominal voltage
**) Sound pressure levels according to EN ISO 11202
9
CAM interface
There is an electrically isolated, bi-directional interface available for communication with the CAM device�
Via two inputs and two outputs, 4 commands can be received from the extraction unit or 4 status informa-
tion can be sent to the CAM machine�
9.1
Pin assignment CAM interface (8, Fig. 1)
Type: RJ45
Pin
1
2
3
4
5
6
7
8
2939 0000
230 V
220 - 240 V
50 / 60 Hz
1610 VA
257 hPa
[3�73 psi]
Description
Out2 - GND
Out2
Out1 - GND
Out1
In2 - GND
In2 - 24 V
In1 - GND
In1 - 24 V
SILENT powerCAM EC
2939 1000
120 V
120 V
50 / 60 Hz
1440 VA
2 x 15 A (T)
54,3 dB(A)
42 mm [1�65 inch]
3984 l/min [2�34 ft³/s]
262 hPa
[3�8 psi]
0�9 m² [1390 sq inch]
Class M according to EN 60335-2-69
7 l [1�85 US gal]
18�0 kg
[39�7 lbs]
270 x 535 x 540 mm
[10�6 x 21�1 x 21�2 inch]
RJ 45 socket
0 - 5 V
15 - 24 V
24 V
5 mA
150 Ohm
- 16 -
2939 2000
100 V
100 V
50 / 60 Hz
1250 VA
255 hPa
[3�70 psi]