9.1.1
Outputs (Out1 / Out2)
The output signals are potential-free switch outputs, in an opto-
coupler, with a 150 Ohm series resistor�
Please see chapter 8, Technical Data, for the maximum pull-up
voltage (U) and the maximum permissible switching current (I)�
The external pull-up resistor (R) must be set so that the maximum
permissible switching current (I) is not exceeded �
9.1.2
Inputs (In1 / In2)
The input signals go to the optocoupler LEDs. See chapter 8, Technical Data, for the specified input volt-
ages of the two signal levels „low"/"high"�
9.2
Control commands / Status information
In1
0 V (low)
24 V (high)
0 V (low)
24 V (high)
Out1
24 V
0 V
24 V
0 V
9.3
Pin assignment interface cable
Interface cable Type A:
Extractor
RJ 45 pin
Pin 8
Pin 7
Interface cable Type B:
Extractor
RJ 45 pin
Pin 8
Pin 7
Interface cable Type C:
Extractor
RJ 45 pin
Pin 8
Pin 7
In2
Commands
0 V (low)
Suction off (turbine off)
0 V (low)
Suction on (turbine on), extraction force level 2
24 V (high)
Carry out cleaning
24 V (high)
Suction on (turbine on), extraction force level 1
Out2
Signal
24 V
Error
24 V
automatic filter cleaning is carried out
0 V
Change fine filter required
0 V
Suction ok
CAM device
Lumberg SV40
(with screw closure)
Pin 1 (+)
Pin 4 (-)
CAM device
Stereo jack
3,5 mm
Pin 1 (+)
Pin 2 (-)
CAM device
9 Pin D-Sub
Pin 4 (+)
Pin 3 (-)
- 17 -