Chapter 3
Fig. 1:
Schematic figures
of the zones for the
IN3000 Direct
safety switch
(example
IN30-E0305K)
158
© SICK AG • Industrial Safety Systems • Germany • Subject to change without notice 8014173/XT35/2013-10-28
Product description
3.3
Enable zone and safe switch off
distance
Legend:
Safety switch
Near range zone
Enable zone
Safe switch off distance s
Actuating element (metal)
The outputs of the safety switch are only enabled on
actuation within the enable zone.
The enable zone and the near range zone are
dependent on the type of safety switch as well as the
material and shape of the actuating element. The use
of different actuating elements (material, shape) will
result in different enable zones.
Typically at an ambient temperature of 20 °C with
non-flush mounting of the safety switch using a
standard plate made of FE360 (= ST37K) according to
EN 60947-5-2:
(12 x 12 x 1 mm) for IN30-E0407K,
(24 x 24 x 1 mm) for IN30-E0305K
(45 x 45 x 1 mm) for IN30-E0208K
or, for flush installation of the safety switch:
(18 x 18 x 1 mm) for IN30-E0306K
Operating instructions
ar
IN3000 Direct