8014173/XT35/2013-10-28 © SICK AG • Industrial Safety Systems • Germany • Subject to change without notice
Technical specifications
Parameter
Enclosure rating according
to IEC 60529
Protection class
Ambient conditions
Environment class as per
EN 60654-1
Salt mist
Height above sea level
Ionizing radiation
Rate of temperature
change
Operating temperature
T
= 10 years
M
T
= 20 years
M
Relative humidity
T
= 10 years
M
T
= 20 years
M
Air pressure
Electrical data
Operating voltage
Supply bridging time
Residual ripple
Reverse polarity
protection
Readiness time after
application of U
B
Short-circuit protection
1)
Evaluation unit e.g. Flexi Classic or Flexi Soft or Failsafe PLC.
Value
IP 65/IP 67
III
C
(application location protected
from the weather)
no
max. 2000 m
not permitted
0.5 K/min
–25 °C ... +70 °C
+10 °C ... +40 °C
5 % ... 95 %
5 % ... 70 %
80 kPa ... 106 kPa
24 V DC (19.2 ... 28.8 V DC)
20 ms
5 %
yes
≤ 1 s
max. 4 A gG