Combination; Standard Supplied Accessories; Optional Accessories; Technical And Electrical Specifications - Panasonic U-5MX4XPQ Manual De Instalación

Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 120
Total capacity/quantity of indoor units
Standard combination of outdoor units
(a)
U-5MX4
U-8MX4
(a)
U-10MX4
(a)
U-12MX4
(a)
U-14MX4
(a)
U-16MX4
(a)
U-18MX4
(a)
U-20MX4
= U-8MX4 + U-12MX4
U-22MX4
= U-10MX4 + U-12MX4
U-24MX4
= U-12MX4 + U-12MX4
U-26MX4
= U-8MX4 + U-18MX4
U-28MX4
= U-10MX4 + U-18MX4
U-30MX4
= U-12MX4 + U-18MX4
U-32MX4
= U-14MX4 + U-18MX4
U-34MX4
= U-16MX4 + U-18MX4
U-36MX4
= U-18MX4 + U-18MX4
U-38MX4
= U-18MX4 + U-12MX4 + U-12MX4
U-40MX4
= U-10MX4 + U-12MX4 + U-12MX4
U-42MX4
= U-12MX4 + U-12MX4 + U-12MX4
U-44MX4
= U-8MX4 + U-18MX4 + U-18MX4
U-46MX4
= U-10MX4 + U-18MX4 + U-18MX4
U-48MX4
= U-12MX4 + U-18MX4 + U-18MX4
U-50MX4
= U-14MX4 + U-18MX4 + U-18MX4
U-52MX4
= U-16MX4 + U-18MX4 + U-18MX4
U-54MX4
= U-18MX4 + U-18MX4 + U-18MX4
(a) = main unit
NOTE
The table above shows the possible total capacity
and number of possible indoor units when
configured in a standard combination.
Refer to the service manual for more details when
using a configuration other than a standard

combination.

If the total capacity of the connected indoor units
exceeds the capacity of the outdoor unit, cooling
and heating performance may drop when running
the indoor units.
Refer to the section on performance charac-
teristics in the Engineering Data Book for details.
There are restrictions on the refrigerant pipe
connection order between outdoor units during
installation in case of a multiple outdoor unit
system.
Install according to the following restrictions.
The capacities of outdoor units A, B, and C must
fulfill the following restriction conditions: A≥B≥C.
1 2
1
To indoor units
2
Outdoor unit multi connection piping kit (first
branch)
3
Outdoor unit multi connection piping kit
(second branch)
U-5~18MX4XPQ
Urban Multi air conditioner
4PW28163-1C
Total
Total
capacity of
quantity of
indoor units
indoor units
62,5~162,5
12
100~260
20
125~325
25
150~390
30
175~455
35
200~520
40
225~585
45
250~650
40
275~715
44
300~780
48
325~845
52
350~910
56
375~975
60
400~1040
64
425~1105
64
450~1170
64
475~1235
61
500~1300
64
525~1365
64
550~1430
64
575~1495
64
600~1560
64
625~1625
64
650~1690
64
675~1755
64
A
B
C
3
1.2.

Standard supplied accessories

See location 1 in figure 24 for reference to where following
accessories are supplied with the unit.
Installation manual
Operation manual
Additional refrigerant charge label
See location 2 in figure 24 for reference to where following
accessories are supplied with the unit.
Gas side accessory pipe
Unit type
5~18 Hp
5~10 Hp
12~18 Hp
Liquid side accessory pipe
Unit type
5~18 Hp
5~10, 14, 16 Hp
12, 18 Hp
1.3.

Optional accessories

To install the above outdoor units, the following optional parts are
also required.
Refrigerant branching kit (for R410A only: Always use an
appropriate kit dedicated for your system.)
Refnet header
CZ-P29HK12Q
CZ-P64HK12Q
CZ-P75HK12Q
Outdoor unit multi connection piping kit (For R410A only: Always
use an appropriate kit dedicated for your system.)
Number of outdoor units connected
2
CZ-32PJ4PQ
Pipe size reducer (For R410A only: Always use an appropriate
kit dedicated for your system.)
U-24~54MX4
CZ-P75BK12Q
To select an optimum refrigerant branching kit, refer to "6. Refrigerant
piping" on page 4.
1.4.
Technical and Electrical specifications
Refer to the Engineering Data Book for the complete list of
specifications.
2.
M
AIN COMPONENTS
For main components and function of the main components, refer to
the Engineering Data Book.
1
1
1
Item
Quantity
1
1
1
Item
Quantity
1
1
1
Refnet joint
CZ-P20BK12Q
CZ-P29BK12Q
CZ-P64BK12Q
CZ-P75BK12Q
3
CZ-48PJ4PQ
CZ-P75HK12Q
Installation manual
2

Hide quick links:

Tabla de contenido
loading

Este manual también es adecuado para:

U-8mx4xpqU-10mx4xpqU-12mx4xpqU-14mx4xpqU-16mx4xpqU-18mx4xpq

Tabla de contenido