Information for Operators

Using these operating instructions as a
starting point, instruct all operators of the
unit with regard to the area of application,
the possible hazards during operation, and
the proper operation of the dust extractor.
1. Setup and
Commissioning

1.1 Setup

Remove the unit and all accessories from the ship-
ping package.
Inspect the delivery for completeness (refer to the
"Standard Delivery" Section).
The unit is fully operational upon delivery.
Select a setup location for the Silent TS
where the exhaust air vent is not blocked.
Where the unit is to be installed in a cabinet, an
opening with the following minimum dimensions must
be provided:
• Circular opening:
• Rectangular opening: At least 170 x 65 mm.
The Silent TS is a free-standing unit intended to be
set up on the floor (e.g., under a workbench).
Particularly after installation of the roller
set (refer to the accessories list), the dust
extractor may only be operated if it is
standing on the floor.
1.2 Connection to the
Extraction Point
Use the included suction hose to connect the unit to
the extraction point.
• Push the suction hose onto the extractor connec-
tion fitting on the dust extractor (fig. 1).
• Connect the suction hose to the desired extraction
point (e.g., Dustex master plus, extractor clamp,
etc.).
With the aid of an extractor switch or a Y-junction it is
possible to connect up to two suction points, or if nec-
essary, use a universal adapter for connector tubes
(see accessories).
Never operate the Silent TS without a suc-
tion hose.
Avoid steep pitches or hanging points
along the hose path. Never kink the hose
and make sure it is never stretched or
under tension when connected.
EN

Operating Instructions

Diameter at least 120 mm
Please have these operating instructions readily
available for the operators.
Additional information can be found in the Section,
"Information for Operators",
at the end of these instructions.

1.3 Electrical Connection

Before connecting the unit to the wall
outlet, make sure the voltage information
on the nameplate corresponds to your local
power supply.
Arrange conducting parts (mains outlets, plugs and
couplings) and install extension cord such that the
protection class (IP) is retained.
• Unroll the power cord.
• Press the OFF switch (fig. 2A).
• Plug the power cord into the wall outlet (fig. 3).
The Silent TS is now ready for continuous
operation.
1.4 Connecting electrical
equipment
Electronic equipment (electrical dust-generating
equipment) can be connected to the Silent TS at the
coupler socket at the back of the machine (N, fig. 4).
In the automatic mode, extraction starts automatically
when a connected electric device is switched on.
Section D.2 at the end of these instructions offers
information concerning electrical systems employing
different power plug designs.
When connecting electrically operated
equipment to the dust extractor, please ob-
serve the operating instructions and safety
information provided with the equipment.
The unit power outlet is to be used only for
connecting electric, dust-generating devic-
es to be operated in conjunction with the
dust extractor.
The unit power outlet is live once the Silent
TS has been connected to the power supply
– even when the Silent TS is switched off.
This allows connected devices to be operat-
ed without extraction for brief periods.
Power consumption of all devices connect-
ed to the unit power outlet may not exceed
the rated value printed next to the unit pow-
er outlet.
- 2 -