4. Parameter address map
JP-8080 (Model ID = 00H 06H)
* Data of addresses marked by # is divided into two bytes for transmission. If the most significant bit of the original data is 1, transmit 01H and the remaining 7 bits as is. If the most
significant bit is 0, transmit 00H and the remaining 7 bits as is.
Example)
If the original data is BCH, the binary expression of BCH is 10111100. Thus, 01H is transmitted as the first byte. As the next byte, we transmit the remaining 0111100 = 3CH without change.
For reception, data will be ignored if the two bytes are not received together.
* Parameter names given as Ñ- are parameters which are used only by the JP-8000. They will be ignored if received by the JP-8080.
+-------------------------------------------------------------------------------+
| Start
|
|
Address |
|===============|===============================================================|
| 00 00 00 00
| System Area
|---------------|---------------------------------------------------------------|
| 01 00 00 00
| Performance Temporary Area
|---------------|---------------------------------------------------------------|
| 02 00 00 00
| User Patch (Patch U:A11 - U:B88)
| 03 00 00 00
| User Performance (Performance U:11 - U:88)
|---------------|---------------------------------------------------------------|
| 09 00 00 00
| Motion Control Data (Motion A, Motion B)
+-------------------------------------------------------------------------------+
4-1. System Area
+-------------------------------------------------------------------------------+
| Offset
|
|
Address |
|===============|===============================================================|
| 00 00 00 00
| System Parameter
| 00 00 20 00
| Motion Setup
| 00 00 30 00
| Tx/Rx Setting
+-------------------------------------------------------------------------------+
4-1-1. System Parameter
+---------------------------------------------------------------------------------------------------------------+
| Offset
|
|
Address | Parameter Name
|===============|=======================================|===============|=======================================|
| 00 00 00 00
| Performance Bank
| 00 00 00 01
| Performance No.
| 00 00 00 02
| Performance Control Channel
| 00 00 00 03
| Power Up Mode
| 00 00 00 04
| MIDI Sync
| 00 00 00 05
| Local Switch
| 00 00 00 06
| Tx/Rx Edit Mode
| 00 00 00 07
| Tx/Rx Edit Switch
| 00 00 00 08
| Tx/Rx Program Change Switch
| 00 00 00 09
| ---
| 00 00 00 0A
| Master Tune
| 00 00 00 0B
| Pattern Trigger Quantize
| 00 00 00 0C
| Motion Restart
| 00 00 00 0D
| Motion Set
| 00 00 00 0E
| Gate Time Ratio
| 00 00 00 0F
| Input Quantize
| 00 00 00 10
| Pattern Metronome
| 00 00 00 11
| Motion Metronome
| 00 00 00 12
| ---
| 00 00 00 13
| ---
| 00 00 00 14
| ---
| 00 00 00 15
| ---
| 00 00 00 16
| ---
| 00 00 00 17
| Performance Group No.
| 00 00 00 18
| Remote Keyboard Channel
+---------------------------------------------------------------------------------------------------------------+
(*) The range of Performance Group numbers will be as follows depending on the Performance Bank value.
ÑÑÑÑÑÑÑÑÑÑÑÑÑÑÑÑÑÑÑ-
Perf. Bank
Perf Group No.
ÑÑÑÑÑÑÑÑÑÑÑÑÑÑÑÑÑÑÑ-
01H: USER
00H only
02H: PRESET
00H - 02H
03H: CARD (S2M-5)
00H - 1FH
03H: CARD
(S4M-5)
00H - 3FH
ÑÑÑÑÑÑÑÑÑÑÑÑÑÑÑÑÑÑÑ-
4-1-2. Motion Setup
+---------------------------------------------------------------------------------------------------------------+
| Offset
|
|
Address | Parameter Name
|===============|=======================================|===============|=======================================|
| 00 00 00 00
| Motion Control A1 Loop length
| 00 00 00 01
| Motion Control A2 Loop length
| 00 00 00 02
| Motion Control B1 Loop length
| 00 00 00 03
| Motion Control B2 Loop length
+---------------------------------------------------------------------------------------------------------------+
204
Description
Description
size = 19H (25 byte)
|
| Sys.Ex.Value
| 01h - 03h
| 00h - 3Fh
| 00h - 10h
| 00h - 01h
| 00h - 02h
| 00h - 01h
| 00h - 01h
| 00h - 01h
| 00h - 02h
| ---
| 00h - 64h
| 00h - 02h
| 00h - 01h
| 00h - 01h
| 00h - 05h
| 00h - 06h
| 00h - 08h
| 00h - 08h
| ---
| ---
| ---
| ---
| ---
| 00h - 3Fh
| 00h - 10h
size = 04H (4 byte)
|
| Sys.Ex.Value
| 00h - 08h
| 00h - 08h
| 00h - 08h
| 00h - 08h
|
|
4-1
|
4-2
|
4-4
|
4-5
|
4-6
|
|
|
4-1-1
|
4-1-2
|
4-1-3
|
|
| Meaning of Value
| USER, PRESET, CARD
| 11 - 88
| 1 - 16, OFF
| PERFORM U-11, LAST-SET
| OFF, MIDI IN, REMOTE KBD IN
| OFF, ON
| MODE1, MODE2
| OFF, ON
| OFF, PC, BANK SEL + PC
| ---
| 427.5 - 452.9 [Hz]
| OFF, BEAT, MEASURE
| OFF, ON
| SET A, SET B
| REAL, STACCATO, 33%, 50%, 66%, 100%
| OFF, 1/16(3), 1/16, 1/8(3), ..., 1/4
| Beep VOL4 - 1, OFF, Click VOL1 - 4
| Beep VOL4 - 1, OFF, Click VOL1 - 4
| ---
| ---
| ---
| ---
| ---
| Group 1..64 (*)
| 1 - 16, ALL
|
| Meaning of Value
| PLAY ONCE, 1 - 8 [measure]
| PLAY ONCE, 1 - 8 [measure]
| PLAY ONCE, 1 - 8 [measure]
| PLAY ONCE, 1 - 8 [measure]
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|