•
If there is any gap, do the following:
– Loosen the locking screw (20) with an Allen key (S=2mm).
– Tighten the screw (21) with an Allen key (S=4mm) with the force necessary
to ensure that the adapter fits tightly against the lens. The clamping forces
should be 1 Nm.
– Tighten the locking screw (20).
•
The effort can be tested with a torque screwdriver.
•
Insert the attachment firmly into the adapter so that the pins located in the
adapter case fit into the grooves (23) of the attachment. Turn the attachment
clockwise as far as it will go. The triangular mark on the attachment and the
square on the adapter body must be aligned.
•
To align the attachment, turn the handle (22) to the OPEN position and align
the attachment with the horizon.
17
Selection Table for Riflescope Inserts
Cover adapter
model
Cover adapter FN
42mm
16
18
20
19
21
The internal diameter of the insert needs to match the
outer diameter of the objective lens housing of the
daylight riflescope it is being installed on.
Insert internal
Suitable for lens housing of daylight
diameter, mm
riflescopes with an outer diameter of, mm
45.5
45.5
46
46
46.5
46.5
47
46.7-47.6
48
47.7-46.7
49
48.7-49.6
50
49.7-50.6
23
2
Open
Close
22
6
ENGLISH