Unit Repair And Excluded Liability - Siemens SITRANS L 260 Guia De Inicio Rapido

Ocultar thumbs Ver también para SITRANS L 260:
Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 75
• Launch SIMATIC PDM – Manager Device Catalog, browse to the unzipped EDD file and
select it.
Configuring a new device
1.
Launch SIMATIC PDM and create a new project for LR260. Application Guides for setting
up PROFIBUS PA devices with SIMATIC PDM can be downloaded from the product page
of our website at: www.siemens.com/LR260.
2.
Upload parameters to the PC/PG.
3.
Configure the device via the Quick Start wizard.
Quick Start Wizard via SIMATIC PDM
Notes:
• The Quick Start wizard settings are inter-related and changes apply only after you click on
Transfer at the end of step 4.
• Click on BACK to return and revise a setting or Cancel to exit the Quick Start.
Launch SIMATIC PDM, open the menu Device – Quick Start, and follow steps 1 to 4.
: For liquid applications, some parameters must be modified following the Quick Start
Note
Wizard. See full Operating Instructions for details.
Maintenance
SITRANS LR260 requires no maintenance or cleaning under normal operating conditions. If
cleaning becomes necessary under severe operating conditions:
1.
Note the antenna material and the process medium, and select a cleaning solution that
will not react adversely with either.
2.
Remove the device from service and wipe the antenna clean using a cloth and suitable
cleaning solution.

Unit Repair and Excluded Liability

For detailed information, please see the inside back cover.
Page EN-18
SITRANS LR260 (PROFIBUS PA) – QUICK START MANUAL
Quick
Start
A5E32114443
Tabla de contenido
loading

Este manual también es adecuado para:

Sitrans lr260

Tabla de contenido