5.
Mounting and installation
Wall mounting of the Fingerprint control unit
Mount the installation rail (DIN Rail 35mm) on the wall.
The rail serves as a support for the casing of the control unit.
Now fit the control unit onto the rail. Open the unit by pressing the tab.
The internal unit must be mounted in such a way that unauthorised people
are prevented from accessing it.
6. Technical data
Description
Power supply
Input power
Operating temperature
Memory
Security
Protection class
Recognition speed
Life span
Description
Power supply
Input power
Relay
Relay power
Mechanical life span of the relays
Electrical life span of the
relays
Operating temperature
Protection class
Digital inputs
Maximum current to X6 PIN 1
* The maximum input current on pin 1 of the X6 connector must not exceed
3.5A.
The control unit and Fingerprint scanner must be connected using a 4-pole
cable with a minimum diameter of 0.5 mm (approx. 0.14 mm²). For distances
over 50m the cable connected to pins 3 and 4 must have a larger diameter
in order to prevent voltage and current drops. The maximum permitted dis-
tance between the scanner and the control unit is 500m. 1 relay is available
for controlling external devices. It is programmed via the programming menu
on the control unit.
The relay has a voltage-free changeover contact, which can be used as
required . The maximum switching capacity is 250VAC 10A (30V / 2A on
the Integra version).
The connecting cables between the internal unit and external unit must be
laid separately from other electrical cables, since they carry low-voltage sig-
nals that can be impaired by other live cables.
The connections are not protected against reverse polarity!
EN
Measurement
Fingerprint
VAC
8-24
VDC
8-30
W
ca.1
°C
-40 up to +85
Fingerprints
99
FAR
1x 10
-6
FRR
1,4x 10
-2
IP43
s
1-4
Finger scans
approx. 1 million
Measurement
Fingerprint
VAC
9-12
VDC
9-12
W
approx. 2
Number
1
230VAC/ 10A
Switching cycles
10Mill.
Switching cycles
200.000
to 250V/5A
°C
-20 to +70
IP41
-
A
-
7. Connection terminals
Fingerprint scanner
Terminal No.
Function
1
Terminal 1 (BUS)
2
Terminal 2 (BUS)
3
Terminal 3 (Power supply)
4
Terminal 4 (Power supply)
We recommend that only the supplied cables are used to connect Finger-
print scanners. The colours indicated above apply only to these cables.
Fingerprint control unit terminals
X2- X7
Spring terminals
X2: Power supply 9VAC-in: unipolar; no polarity to watch when using a DC
power supply.
Terminal No.
Function
1
Power supply 9-12VAC or 9-12VDC
2
Power supply 9-12VAC or 9-12VDC
X3: BUS for communication with the scanner. Connection with the Finger-
print scanner.
Terminal No
Function
1
RS485 A, Terminal 1
2
RS485 A, Terminal 2
X4: Relay, Voltage-free contact for control of one device.
Terminal No.
Function
1
Common
2
N.O. (normally open) contact
3
N.C. (normally closed) contact
X6: Fingerprint scanner power supply:
Terminal No.
Function
1
Scanner power supply terminal 3
2
Scanner power supply terminal 4
1 verde
2 giallo
3 marrone
4 bianco
11