Care And Maintenance - HELLY HANSEN SAFE 150N Manual Del Usuario

Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 13
HELLY HANSEN INFLATABLE LIFEJACKET
Inflatable lifejacket
USE
The Helly Hansen inflatable lifejacket ensures maximum freedom of movement and is ideal for
use in boats. The jacket can be used in coastal waters/inshore when combined with suitable
clothing. Is not suitable if you are using heavy tools or other equipment. Full performance may not
be acchieved using waterproof clothing or in other circumstances. Refer to the leaflet.
Lifejackets reduce the risk of drowning, but do not guarantee safety in the event of an accident.
150
BUOYANCY
ISO 12401
AUTOMATIC
MANUAL
DECK
HARNESS
USER GUIDELINES
Understanding how to use the lifejacket increases safety. Read the manual and practice using the
vest. The lifejacket must be fully inflated to be fully functional. When inflated, it will turn an
unconscious person over to ensure the correct float position, keeping the mouth well clear of water.
• Train yourself in the use of the device.
• Do not use as a cushion.
• When evacuating at sea with an inflated jacket, keep your arms crossed over the jacket.
• Hang the jacket vertically to dry after use.
• Jackets must not be stored in plastic bags.
• Store jackets in a dark, well-ventilated place.
• Storing and drying in humidity and heat may inflate the jacket.
• Warning: Gas cylinders are dangerous goods. They should be kept away from children and not
be misused.
CHECK BEFORE USE:
Inspect that the jacket is not damaged, and check that the inflation mechanism is ready to use.
See the front page of this booklet which of the three alternatives applies for your lifejacket.
Follow the corresponding instructions on page 1 (United Moulders), 3 (CM Hammar) or 5 (Halkey
Roberts).
DRESS
Put the lifejacket on as you would a normal jacket. Check that the front buckle is properly
closed. Adjust the belt so that it fits tightly around the body. The back strap can be adjusted by
pulling the belt up higher. Attach the crotch straps or leg loops.
SAFETY LINE (IF APPLICABLE)
The safety line (ISO 12401) is designed for protection if you fall overboard – not as a safety line
for falls from great heights. The anchor point must withstand a force of 1000 kg. The line is
unreliable when carried loosely.
United Moulders
Min. 40 kg
33 grm
LEG
CHEST
WEIGHT CARTRIDGE
SPRAY
LOOPS
WIDTH
HOOD
Halkey Roberts
7

CARE AND MAINTENANCE

EN
The lifespan of the lifejacket will be extended if routine maintenance is carried out annually.
Maintenance intervals start from the date of purchase and are as follows:
1. Rinse the lifejacket, especially after use in seawater. Soiled lifejackets can be washed with
soap and water.
Turn off the automatic inflation mechanism (5) before washing (not applicable for CM Hammar).
Jackets must not be dried at high temperatures or under direct heat.
2. Inspect the CO
has not been triggered and that the weight of the cartridge matches the stamped weight.
3. Check the air chamber for excessive wear. Also check straps, stitching and buckles.
4. For professional use, the automatic inflating mechanism (5) must be replaced annually. For
recreational use, we recommend replacement every two years. For CM Hammar inflators
we recomend replacement after five years.
5. Check the air chamber by blowing it up using the inflation tube. Leave the jacket inflated
overnight. If the jacket has a leak, or is otherwise damaged, it must be taken to an importer-
approved service center. Never attempt to repair the jacket yourself.
CROTCH
NB! CO
cartridges must not be triggered once the jacket has been inflated with the filler tube.
STRAP
2
FITTING THE AUTOMATIC INFLATION MECHANISM/REARMING INSTRUCTIONS
United Moulders and Halkey Roberts: (for CM Hammar inflators, see separate page)
1. Check that the trigger arm (3) is in the raised position.
2. Press the colored clip (2) into the groove so that the trigger arm is held in place.
3. Make sure that the CO
4. Screw the CO
Point 5 must only be carried out in dry conditions and with dry hands:
5. Screw the automatic inflation mechanism (5) firmly into place. Ensure that the colored button
(6) is clearly visible. Only use original CO
MAINTENANCE OPERATION AND PACKING
1. Deflate the jacket by turning the valve cap on the inflation tube and pressing it in towards the
tube.
2. Press the air out by rolling the air chamber tightly. Do this a few times to expel all the air.
3. The jacket must be clean and dry.
4. Place the jacket on a flat surface and smooth out the air chamber so that all the creases are
removed.
5. If necessary, refit the automatic inflation mechanism and CO
6. PACKING: Fold the outer edge of the air chamber down and in towards the center.
Then fold from the inner edge and out over the first fold. Close the velcro/zipper on the
sides. Check that the lanyard (1) is visible on the outside of the cover.
Fold the top part of the jacket three times and close with the velcro/zipper.
PACK AFTER USE
For more information, see HELLYHANSEN.COM/LIFEJACKETS
cartridge annually (not applicable for CM Hammar). Look for corrosion, check that it
2
cartridge is not damaged.
2
cartridge firmly in place.
2
cartridges and triggers.
2
Fold towards the center
8
cartridge.
2
Tabla de contenido
loading

Tabla de contenido