PH10 PLUS installation and user's guide
http://www.renishaw.com
PH10 system description
Product
Description
PH10T PLUS
A shank-mounted head with two-wired probe capability and an M8 thread
PH10M PLUS
A shank-mounted head with multiwired probe capability and a Renishaw autojoint
PH10MQ PLUS
A quill-mounted head with multiwired probe capability and a Renishaw autojoint
HCU1
A hand control unit for use with PH10 measurement systems
PHC10-3 PLUS
A controller for use with PH10 measurement systems
The PH10 PLUS range of motorised heads consists of three different models:
Each head in the PH10 PLUS range is a general purpose, versatile unit designed specifically for use on direct computer controlled (DCC)
CMMs and incorporates the following features:
720 indexing positions
0.4 μm indexing repeatability
7.5° indexing steps in both axes
300 mm (maximum) extension bar capability *
* NOTE: 450 mm is possible for PH10M / MQ with special order carbon fibre extensions.
WARNING: The components of the PH10 PLUS system are not compatible with PH9 system components. No attempt should be
made to connect PH10 PLUS system components to a PH9 system, as this will result in damage to the product.
Issued 01 2013