SECTION 5
If only the trigger switch is to be replaced, pull switch from handle assembly and disconnect wires (2)
at the connections. Connect new switch. Either wire can go on either terminal. Reposition switch in
2. Carefully remove the torch body/piston assembly from the handle cavity. Note position of switch,
cables and hose for reinstallation.
If necessary, remove old trigger switch by discon-
necting 2 lugs and replace with new assembly.
handle. Replace the other half of the handle and tighten the screws.
Note:
105
MAINTENANCE
Switch
Spring
Tabla de contenido