2.18
Adjustments, English
(V-SL) Vertical slope
(H-PH) Horizontal phase
(H-AM) Horizontal amplitude
(EW-P) East/West Parabola
(EWUC) East/West Uppercorner
(EWLC) East/West lowercorner
(EW-T) East/West Trapezium
(H-PA) Horizontal parallelogram
Finish the on-site service
Adjust distance N to G = 77.0 mm ± 1.5mm
The value adjust in FORMAT 1.
Adjust distance H to Q = T to F = 20.0 mm ± 2.5mm
EW adjustments might have to be performed more than one time in order to
obtain the optimum result.
Adjust for straight line between A to D and B to C.
Special attention to the middel 2/3 part of the line.
Adjust for straight line in the upper ¼ of the line A to D and B to C.
Compare to the middel 2/3 part of the line.
Adjust for straight line in the lower ¼ of the line A to D and B to C.
Compare to the middel 2/3 part of the line.
Adjust distance A to W + B to X = Z to D + C to Y, or
Distance A to B = D to C.
Adjust distance A to W = Z to D and
distance B to X = C to Y.
- If a non-customer VTR has been used V.TAPE must be set to NONE. Select OPTIONS
in SETUP. Select CONNECTIONS and set V.TAPE to NONE. Press GO to exit SETUP.
- See #7 Check after replacement of main chassis or modules, for fi nishing the
on-site service.