Technical Characteristics - Barazza 1FVCFY Manual De Instrucciones

Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 146

Technical characteristics

Displays
Display 1
1
2
3
CAL
0.5L
1.0L
-L0-
-L0- to –L2
(Water level)
(Water level)
VAP
PUMP
FULL
---
---
Displays
Display 2
---
---
---
---
---
---
---
---/(Temperature or
foodstuff group)
---
Special functions
A1 to A5
to
C1 to C5
to
to
---
---
---
System warnings
Display 3
Descaling
(clock)
(clock)
(clock)
Water level
(Clock or time
setting)
(Clock or time
setting)
Water tank
(Clock or time
setting)
(Clock)
(Time setting)
Heating up
(Time setting)
Steam reduction
(Clock)
(Clock)
(Clock)
(Clock)
(Clock)
(Clock)
(Clock)
(Clock)
(Clock)
(Clock)
(Clock)
Description
Soft water.
Medium water.
Hard water.
Appliance must be descaled.
Flashing – descaling starts.
Feed 0.5 litre descaling solution into the
water tank.
Feed 1 litre cold water into the water tank
for rinsing.
Insufficient water in water tank.
Water level indication: -L4- for a complete
tank and -L1- for low tank level.
Indication that water tank is missing.
The water tank must be removed, emptied
and reinserted.
Special functions with predefined
temperatures and times.
Special functions with predefined
temperatures and times.
Indication that steam reduction process is
ongoing.
Indication that cold water is entering the
boiler and hot water is being pumped to
the water tank.
The water tank must be removed, emptied
and reinserted.
Damaged lamp.
Temperature in the PCB is too high.
Error in the pressure sensor.
Error in the oven's temperature sensor.
Error in the boiler's temperature sensor.
Boiler and Cavity temperature sensors
swapped.
Error in the water tank's level detectors.
Error in the water pump.
EN
33
Tabla de contenido
loading

Tabla de contenido