SICK LCU-P Manual De Instrucciones página 358

Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 127
Chapter 10
Code Fault Message
1 6 3 LOCKOUT: 163
ESPD SENSOR FAI LU RE
168
LOCKOUT: 168
ESPD SENSOR FAI LU RE
175
LO C KOUT: 175
ESPD SENSOR FAI LU RE
180
LOCKOUT: 180
ESPD SENSOR FAI LU RE
2 0 3 LOCKOUT: 203
ESPD SENSOR FAILURE
2 0 4 LOCKOUT: 204
ESPD SENSOR FAILURE
2 0 6 LOCKOUT: 206
ESPD SENSOR FAI LU RE
207
LOCKOUT: 207
ESPD SENSOR FAI LU RE
208
LOCKOUT: 208
ESPD SENSOR FAI LU RE
209
LOCKOUT: 209
ESPD SENSOR FAI LU RE
240
LCU INT. FAULT: 240
REPLACE KEYPAD
241
LCU I NT. FAULT: 241
REPLACE EXT. BOARD
242
LCU INT. FAULT: 242
REPLACE EXT. BOARD
243
LCU INT. FAULT: 243
REPLACE EXT. BOARD
245
LCU INT. FAULT: 245
COMM UN ICATIONS LOST
As a fully electronic system, the LCU is maintenance-free. The regional office
or subsidiary can provide further assis-tance with regard to service.
Moreover, the plug-in terminal rows enable exchanges to be carried out quickly.
358
Diagnostic Messages
Fault Description
Primary AOPD OSSD 1 of a type 2 AOPD failed to
respond to MCC 1.
Primary AOPD OSSD 2 of a type 2 AOPD failed to
respond to MCC 2.
Secondary AOPD OSSD 2 of type 4 failed to respond
to MCC 3.
Secondary AOPD OSSD 2 of a type 2 AOPD failed to
respond to MCC 4.
The secondary ESPD OSSD 1 input is active when
there should be no secondary ESPD attached.
The secondary ESPD OSSD 2 input is active when
there should be no secondary ESPD attached.
Primary 1 AOPD is down in green state.
Primary 2 AOPD is down in green state.
Secondary 1 AOPD is down in green state.
Secondary 2 AOPD is down in green state.
Keypad test failure.
User interface ROM failure.
User interface RAM failure.
User interface RAM failure.
Communications timeout failure.
8 008 364/NB 86/25-04-00 © SICK AG • Safety Systems • Germany • All rights reserved
Operating instructions
LCU-P