SICK LCU-P Manual De Instrucciones página 355

Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 127
Operating instructions
LCU-P
Code Fault Message
7 0
LOCKOUT: 70
CH ECK MUTI NG LAM P
7 1
LOC KO UT: 71
CH ECK MUTI NG LAM P
72
LOCKOUT: 72
CHECK BLANKI NG LAMP
75
LOCKOUT: 75
INVALID OPER. MODE
76
LOCKOUT: 76
INVALID OPER. MODE
80
LOCKOUT: 80
RESET OR POWER DOWN
81
LOCKOUT: 81
RESET OR POWER DOWN
82
LOCKOUT: 82
RESET OR POWER DOWN
84
LOCKOUT: 84
RESET OR POWER DOWN
8 5
LOCKOUT: 85
RESET OR POWER DOWN
96
LOCKOUT: 96
LCU OSSD FAI LU RE
97
LOCKOUT: 97
LCU OSSD FAI LU RE
98
LOCKOUT: 98
LCU OSSD FAI LU RE
99
LOCKOUT: 99
LCU OSSD FAI LU RE
104
LOCKOUT: 104
B1, B2 SEQU ENCE FAI L
105
LOCKOUT: 105
B1, B2 SEQU ENCE FAI L
106
LOCKOUT: 106
B1, B2 SEQU ENCE FAI L
107
LOCKOUT: 107
B1, B2 SEQU ENCE FAI L
112
LOCKOUT: 112
CHANGE CONTROLBOARD
113
LOCKOUT: 113
CHANGE CONTROLBOARD
8 008 364/NB 86/25-04-00 © SICK AG • Safety Systems • Germany • All rights reserved
Diagnostic Messages
Fault Description
Muting indicator is showing an invalid reading.
The muting indicator is active but one safety channel
is not in a muting operating mode.
No Reduced Resolution/ Blanking indicator is detected.
The AOPD is not in green state when the LCU-P is in
green state.
The AOPD and LCU- P in different modes.
One safety channel has detected that the other safety
channel is in Lockout.
Setup data in RAM did not match setup data in NVRAM.
A comparison of the current configuration with the
previous configuration failed.
The PC has requested operating history data from a
safety channel.
The PC or UI has requested that all of NVRAM be
initialized to factory defaults.
LCU OSSD 1 should be energised in green state.
LCU OSSD 2 should be energised in green state.
LCU OSSD 1 was energised in non green state.
LCU OSSD 2 was energised in non green state.
Invalid transition B1 is "on" B2 was "off " and went
"on" again before B1 went "off ".
Invalid transition B2 is "off " B1 was "on" and went
"off " before B2 went "on".
Invalid transition B2 is "on" B1 was "off " and went
"on" before B2 went "off ".
Invalid transition B1 is "off " B2 was "on" and went
"off " before B1 went "on".
The CRC of the setup and operating history
configurations in NVRAM did not match calculated value.
LCU-P OSSD 1 is registering an over current condition.
GB
Chapter 10
355
Tabla de contenido
loading

Tabla de contenido